Clinical cancer research : an official journal of the American Association for Cancer Research · 2007
In vivo 19F magnetic resonance spectroscopy and chemical shift imaging of tri-fluoro-nitroimidazole as a potential hypoxia reporter in solid tumors.
СтатьяПоддержка NIH: внешняя программаНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Procissi Daniel, Claus Filip, Burgman Paul, Koziorowski Jacek, Chapman J Donald, Thakur Sunitha B, Matei Cornelia, Ling C Clifton, Koutcher Jason A
Аннотация
PURPOSE: 2-Nitro-alpha-[(2,2,2-trifluoroethoxy)methyl]-imidazole-1-ethanol (TF-MISO) was investigated as a potential noninvasive marker of tissue oxygen levels in tumors using (19)F magnetic resonance spectroscopy (MRS) and (19)F chemical shift imaging.
EXPERIMENTAL DESIGNS: In vitro data were obtained using high-performance liquid chromatography on tumor cells incubated under varying oxygen conditions to determine the oxygen-binding characteristics. In vivo data were obtained using a well-characterized hypoxic murine breast tumor (MCa), in addition to studies on a rat prostate tumor model (R3327-AT) implanted in nude mice. Detection of intratumor (19)F signal from TF-MISO was done using MRS for up to 10 h following a 75 mg/kg i.v. injection. Localized distribution of the compound in the implanted MCa tumor has been imaged using slice-selective two-dimensional chemical shift imaging 6 h after injection.
RESULTS: The in vitro results showed that TF-MISO preferentially accumulates in cells incubated under anoxic conditions. The in vivo (19)F MR spectral features (line width and chemical shift) were recorded as a function of time after injection, and the results indicate that the fluorine atoms are indeed sensitive to changes in the local environment while still providing a detectable MR signal. Ex vivo spectra were collected and established the visibility of the (19)F signal under conditions of maximum hypoxia. Late time point (>6 h) tumor tissue concentrations, as obtained from (19)F MRS, suggest that TF-MISO is reduced and retained in hypoxic tumor. The feasibility of obtaining TF-MISO tumor distribution maps in a reasonable time frame was established.
CONCLUSIONS: Based on the results presented herein, it is suggested that TF-MISO has the potential to be a valid magnetic resonance hypoxia imaging reporter for both preclinical hypoxia studies and hypoxia-directed clinical therapy.
EXPERIMENTAL DESIGNS: In vitro data were obtained using high-performance liquid chromatography on tumor cells incubated under varying oxygen conditions to determine the oxygen-binding characteristics. In vivo data were obtained using a well-characterized hypoxic murine breast tumor (MCa), in addition to studies on a rat prostate tumor model (R3327-AT) implanted in nude mice. Detection of intratumor (19)F signal from TF-MISO was done using MRS for up to 10 h following a 75 mg/kg i.v. injection. Localized distribution of the compound in the implanted MCa tumor has been imaged using slice-selective two-dimensional chemical shift imaging 6 h after injection.
RESULTS: The in vitro results showed that TF-MISO preferentially accumulates in cells incubated under anoxic conditions. The in vivo (19)F MR spectral features (line width and chemical shift) were recorded as a function of time after injection, and the results indicate that the fluorine atoms are indeed sensitive to changes in the local environment while still providing a detectable MR signal. Ex vivo spectra were collected and established the visibility of the (19)F signal under conditions of maximum hypoxia. Late time point (>6 h) tumor tissue concentrations, as obtained from (19)F MRS, suggest that TF-MISO is reduced and retained in hypoxic tumor. The feasibility of obtaining TF-MISO tumor distribution maps in a reasonable time frame was established.
CONCLUSIONS: Based on the results presented herein, it is suggested that TF-MISO has the potential to be a valid magnetic resonance hypoxia imaging reporter for both preclinical hypoxia studies and hypoxia-directed clinical therapy.