MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.aca.2023.342117

Медицинская библиотека · Analytica chimica acta · 2023

Improved quantification of carbonyl sub-metabolome by liquid chromatography mass spectrometry using a fragment controlled multiplexed isotopic tag.

Tian Xiaobo, Hopfgartner Gérard

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Carbonyl-containing metabolites are a class of key intermediate in metabolism, which has potentials to be biomarkers. Since their poor ionization, derivatization reagents, such as dansylhydrazine, are usually used to improve the sensitivity and/or to facilitate quantification. However, most current carbonyl derivatization reagents only have two channels, one is isotopically labeled and the other one is non-labeled. To quantify more samples in a run and using data-independent acquisition (DIA) mode to get comprehensive and unbiased mass fragmentation, we proposed a fragment-controlled isotopic tag, called DiMe-FP-NHNH2 (FP) which has five channels: Δ0, Δ3, Δ6, Δ9, and Δ12, thus up to 5 samples can be analyzed in a run.

RESULTS

The most important improvement is that the FP tag can produce multiple characteristic signals in tandem mass, diagnostic ions and neutral losses, which helps to selectively detect aldehydes/ketones for targeted and untargeted analysis. To exhibit all capabilities of the FP tag, we mimicked an untargeted metabolomics experiment, which comprises two steps. First, discovery step, using Data-Independent Analysis (SWATH-MS) and the labeling of two channels (Δ0 and Δ3), we picked out aldehyde/ketone from the pooled urine samples based on three characteristic signals, including isotope patterns, diagnostic ions, and neutral losses. Second, five-plex quantification, relative and absolute quantification were achieved in a single LC-MS analysis. Notably, because of different nominal masses, the FP tag can be used on any low or high resolution mass spectrometers.

SIGNIFICANCE: The benefits and performance of the FP tag are demonstrated by the analysis of urine samples collected from patients from a prostate cancer study, in which more than a thousand features were found based on MS1 fingerprint, but only around 120 aldehyde/ketone candidates were confirmed with characteristic signals and nine of which were quantified showing significant differences from healthy and reference urine samples.

Для цитирования: Tian Xiaobo, Hopfgartner Gérard. Improved quantification of carbonyl sub-metabolome by liquid chromatography mass spectrometry using a fragment controlled multiplexed isotopic tag.. Analytica chimica acta. 2023. DOI: 10.1016/j.aca.2023.342117.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.