BACKGROUND

Pelvic morphological parameters on magnetic resonance imaging (MRI), such as the membranous urethral length (MUL), can predict urinary incontinence after radical prostatectomy but are prone to interobserver disagreement. Our objective was to improve interobserver agreement among radiologists in measuring pelvic parameters using deep learning (DL)-based segmentation of pelvic structures on MRI scans.

METHODS

Preoperative MRI was collected from 167 prostate cancer patients undergoing radical prostatectomy within our regional multicentric cohort. Two DL networks (nnU-Net) were trained on coronal and sagittal scans and evaluated on a test cohort using an 80/20% train-test split. Pelvic parameters were manually measured by three abdominal radiologists on raw MRI images and with the use of DL-generated segmentations. Automated measurements were also performed for the pelvic parameters. Interobserver agreement was evaluated using the intraclass correlation coefficient (ICC) and the Bland-Altman plot.

RESULTS

The DL models achieved median Dice similarity coefficient (DSC) values of 0.85-0.97 for coronal structures and 0.87-0.98 for sagittal structures. When radiologists used DL-generated segmentations of pelvic structures, the interobserver agreement for sagittal MUL improved from 0.64 (95% confidence interval 0.28-0.83) to 0.91 (95% CI 0.84-0.95). Furthermore, there was an increase in ICC values for the obturator internus muscle from 0.74 (95% CI 0.42-0.87) to 0.86 (95% CI 0.75-0.92) and for the levator ani muscle from 0.40 (95% CI 0.05-0.66) to 0.61 (95% CI 0.31-0.78).

CONCLUSIONS

DL-based automated segmentation of pelvic structures improved interobserver agreement in measuring pelvic parameters on preoperative MRI scans.

RELEVANCE STATEMENT: The implementation of deep learning segmentations allows for more consistent measurements of pelvic parameters by radiologists. Standardized measurements are crucial for incorporating these parameters into urinary continence prediction models.

KEY POINTS: • DL-generated segmentations improve interobserver agreement for pelvic measurements among radiologists. • Membranous urethral length measurement improved from substantial to almost perfect agreement. • Artificial intelligence enhances objective pelvic parameter assessment for continence prediction models.

Для цитирования: van den Berg Ingeborg, Spaans Robert N, Wessels Frank J, van der Hoeven Erik J R J, Nolthenius Charlotte J Tutein, van den Bergh Roderick C N, van der Voort van Zyp Jochem R N, van den Berg Cornelis A T, van Melick Harm H E. Automated pelvic MRI measurements associated with urinary incontinence for prostate cancer patients undergoing radical prostatectomy.. European radiology experimental. 2024. DOI: 10.1186/s41747-023-00402-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.