MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circulationaha.107.702720

Медицинская библиотека · Circulation · 2007

Aortic diameter >or = 5.5 cm is not a good predictor of type A aortic dissection: observations from the International Registry of Acute Aortic Dissection (IRAD).

Pape Linda A, Tsai Thomas T, Isselbacher Eric M, Oh Jae K, O'gara Patrick T, Evangelista Arturo, Fattori Rossella, Meinhardt Gabriel, Trimarchi Santi, Bossone Eduardo, Suzuki Toru, Cooper Jeanna V, Froehlich James B, Nienaber Christoph A, Eagle Kim A, International Registry of Acute Aortic Dissection (IRAD) Investigators

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Studies of aortic aneurysm patients have shown that the risk of rupture increases with aortic size. However, few studies of acute aortic dissection patients and aortic size exist. We used data from our registry of acute aortic dissection patients to better understand the relationship between aortic diameter and type A dissection.

METHODS AND

RESULTS

We examined 591 type A dissection patients enrolled in the International Registry of Acute Aortic Dissection between 1996 and 2005 (mean age, 60.8 years). Maximum aortic diameters averaged 5.3 cm; 349 (59%) patients had aortic diameters <5.5 cm and 229 (40%) patients had aortic diameters <5.0 cm. Independent predictors of dissection at smaller diameters (<5.5 cm) included a history of hypertension (odds ratio, 2.17; 95% confidence interval, 1.03 to 4.57; P=0.04), radiating pain (odds ratio, 2.08; 95% confidence interval, 1.08 to 4.0; P=0.03), and increasing age (odds ratio, 1.03; 95% confidence interval, 1.00 to 1.05; P=0.03). Marfan syndrome patients were more likely to dissect at larger diameters (odds ratio, 14.3; 95% confidence interval, 2.7 to 100; P=0.002). Mortality (27% of patients) was not related to aortic size.

CONCLUSIONS

The majority of patients with acute type A acute aortic dissection present with aortic diameters <5.5 cm and thus do not fall within current guidelines for elective aneurysm surgery. Methods other than size measurement of the ascending aorta are needed to identify patients at risk for dissection.

Для цитирования: Pape Linda A, Tsai Thomas T, Isselbacher Eric M, Oh Jae K, O'gara Patrick T, Evangelista Arturo, Fattori Rossella, Meinhardt Gabriel, Trimarchi Santi, Bossone Eduardo, Suzuki Toru, Cooper Jeanna V, Froehlich James B, Nienaber Christoph A, Eagle Kim A, International Registry of Acute Aortic Dissection (IRAD) Investigators. Aortic diameter >or = 5.5 cm is not a good predictor of type A aortic dissection: observations from the International Registry of Acute Aortic Dissection (IRAD).. Circulation. 2007. DOI: 10.1161/circulationaha.107.702720.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.