MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2024.07.024

Медицинская библиотека · Heart rhythm · 2024

Focal pulsed field ablation in complex atrial tachycardia: First clinical experience and 1-year outcome.

Erhard Nico, Englert Florian, Prommersberger Simon, Popa Miruna, Bourier Felix, Reents Tilko, Kraft Hannah, Martinez Alex Tunsch, Syväri Jan, Tydecks Madeleine, Abdiu Edison, Koops Eva, Reiter Theresa, Telishevska Marta, Lengauer Sarah, Hessling Gabriele, Deisenhofer Isabel, Bahlke Fabian

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Pulsed field ablation (PFA) has become increasingly important in the treatment of cardiac arrhythmias. In addition to single-shot devices mainly used for pulmonary vein isolation, focal PFA may provide a treatment option that increases the versatility of the technique.

OBJECTIVE

The purpose of this study was to provide data on feasibility, safety, and long-term outcome of focal PFA for ablation of complex atrial tachycardia (AT).

METHODS

All consecutive patients (n = 34) with complex AT treated at our department between 2022 and 2023 with a focal PFA system (CENTAURI™, Galvanize Therapeutics) were included. The majority of patients (32/34) previously had undergone at least 1 radiofrequency ablation. Established contact force-sensing catheters were used for PFA application in combination with a PFA generator. Pulsed electric field trains were conducted in a R-wave triggered manner.

RESULTS

Acute procedural success was accomplished in all patients. PFA included creation of 51 linear lesions and (re)isolation of 12 pulmonary veins. Mean procedural duration was 102.7 ± 30.3 minutes, with left atrial dwell time of 75.0 ± 24.7 minutes. Mean fluoroscopy duration was 8.7 ± 5.3 minutes. No complications occurred. After mean follow-up of 340.9 ± 130.1 days, recurrence of any AT occurred in 15 patients (44.1%). During 9 reablations, 3 gaps in previously created linear lesions were detected; the majority of recurrences (n = 6) were not related to previous PFA lesion creation.

CONCLUSION

Focal PFA of complex AT substrates was safe and efficient. Acute procedural success was 100%. After 1 year, the majority of patients were in sinus rhythm. A minority of recurrences was caused by insufficient PFA lesion creation.

Для цитирования: Erhard Nico, Englert Florian, Prommersberger Simon, Popa Miruna, Bourier Felix, Reents Tilko, Kraft Hannah, Martinez Alex Tunsch, Syväri Jan, Tydecks Madeleine, Abdiu Edison, Koops Eva, Reiter Theresa, Telishevska Marta, Lengauer Sarah, Hessling Gabriele, Deisenhofer Isabel, Bahlke Fabian. Focal pulsed field ablation in complex atrial tachycardia: First clinical experience and 1-year outcome.. Heart rhythm. 2024. DOI: 10.1016/j.hrthm.2024.07.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.