MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mat.0000000000001380

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2021

Viscoelastic Coagulation Monitor as a Novel Device to Assess Coagulation at the Bedside. A Single-Center Experience During the COVID-19 Pandemic.

Panigada Mauro, Meli Andrea, Scotti Eleonora, Properzi Paolo, Brioni Matteo, Kamel Shady, Ghirardello Stefano, Scudeller Luigia, Dalton Heidi J, Grasselli Giacomo

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

Viscoelastic coagulation monitor (VCM) is a portable device developed to evaluate the viscoelastic properties of whole blood activated by contact with glass. In this study, VCM was employed to analyze the viscoelastic profiles of 36 COVID-19 intensive care patients. Full anticoagulant dose heparin (unfractionated [UFH]; low molecular weight [LMWH]) was administrated to all patients. The association between VCM and laboratory parameters was retrospectively analyzed. The administration of UFH-influenced VCM parameters prolonging clotting time (CT) and clot formation time (CFT) and reducing angle (alpha) and amplitudes of the VCM tracings (A10, A20, and maximum clot firmness [MCF]) compared with LMWH therapy. A tendency toward hypercoagulation was observed by short CT and CFT in patients receiving LMWH. Clotting time was correlated with UFH dose (Spearman's rho = 0.48, p ≤ 0.001), and no correlation was found between CT and LMWH. All VCM tracings failed to show lysis at 30 and 45 minutes, indicating the absence of fibrinolysis. A10, A20, and MCF exhibited very-good to good diagnostic accuracy for detecting platelet count and fibrinogen above the upper reference limit of the laboratory. In conclusion, VCM provided reliable results in COVID-19 patients and was easy to perform with minimal training at the bedside.

Для цитирования: Panigada Mauro, Meli Andrea, Scotti Eleonora, Properzi Paolo, Brioni Matteo, Kamel Shady, Ghirardello Stefano, Scudeller Luigia, Dalton Heidi J, Grasselli Giacomo. Viscoelastic Coagulation Monitor as a Novel Device to Assess Coagulation at the Bedside. A Single-Center Experience During the COVID-19 Pandemic.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2021. DOI: 10.1097/mat.0000000000001380.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.