MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13089-025-00429-1

Медицинская библиотека · The ultrasound journal · 2025

WINFOCUS worldwide survey on central venous catheter insertion and position confirmation practices (CVC-ICON study).

Corradi Francesco, Cucciolini Giada, Tavazzi Guido, Wong Adrian, Balan Cosmin, Melniker Lawrence A, Hussain Arif, Noor Julina Md, Bailey Jacob John, Abdo Cuza Anselmo A, Goffi Alberto, Via Gabriele

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Central venous catheters (CVC) are essential in medicine for monitoring, drug and fluid administration, and renal replacement therapy. Complications such as arrhythmias, endothelial damage, thrombosis, or hemothorax might arise from incorrect positioning. Despite evidence showing their reduction using ultrasound to guide insertion and correct tip positioning, and greater accuracy for tip position assessment vs. chest-X-ray (CXR), ultrasound adoption greatly varies worldwide. This study, conducted by the World Interactive Network Focused On Critical Ultrasound (WINFOCUS) aimed to assess global practices in CVC insertion and tip position confirmation.

METHODS

A web-based survey was conducted (April-September 2023) among WINFOCUS members/affiliates across five continents. It assessed clinical backgrounds, CVC insertion and tip position check methods, and reasons for not using ultrasound. Developed by WINFOCUS Research sub-committee, the survey was emailed, with two reminders. Data were analyzed using SPSS 27.0.

RESULTS

A total of 1,227 respondents (5.1% response rate) participated, mainly from Europe (33.5%), Asia (28.3%), and the Americas (30.9%), with 95.4% being physicians. Over half (51.3%) had over six years of experience and placed over 200 CVC, mostly using ultrasound guidance (70% of cases). The internal jugular vein (IJV) was the preferred insertion site (74%). Ultrasound was used for pre-insertion assessment (55%) and vessel puncture (57%) but less for guidewire confirmation (44%). CXR remained the primary method for tip position assessment (52%), while only 12% relied solely on bedside ultrasound. Barriers to exclusive ultrasound use included institutional guidelines (33.9%) and medico-legal concerns (13.8%).

CONCLUSIONS

Despite evidence favoring ultrasound for CVC insertion and tip position confirmation, its use remains inconsistent, with CXR still widely used. This survey underscores the need for standardized protocols and training to enhance US adoption, improve patient safety, and reduce CXR reliance.

Для цитирования: Corradi Francesco, Cucciolini Giada, Tavazzi Guido, Wong Adrian, Balan Cosmin, Melniker Lawrence A, Hussain Arif, Noor Julina Md, Bailey Jacob John, Abdo Cuza Anselmo A, Goffi Alberto, Via Gabriele. WINFOCUS worldwide survey on central venous catheter insertion and position confirmation practices (CVC-ICON study).. The ultrasound journal. 2025. DOI: 10.1186/s13089-025-00429-1.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.