Volgmann Constanze, Barten Markus J, Al Assar Yousuf, Grahn Hanno, Metzner Andreas, Söffker Gerold, Schulte-Uentrop Leonie, Magnussen Christina, Kirchhof Paulus, Kluge Stefan, Doll Susanne, Doll Nicolas, Reichenspurner Hermann, Bernhardt Alexander M

Аннотация

BACKGROUND: In patients with cardiogenic shock the clinical treatment often involves temporary mechanical circulatory support for initial haemodynamic stabilization to enable further assessment of therapeutic strategies. The surgically implanted Impella 5.5 can be used for several indications like ventricular unloading, haemodynamic support during high-risk interventions, and as a bridge-to-transplant strategy.We present an interdisciplinary managed case of using Impella 5.5 for multiple indications and treatment strategies in one patient.

CASE SUMMARY: A 66-year-old patient with known dilated cardiomyopathy was admitted with non-ST-elevation myocardial infarction and underwent urgent coronary bypass grafting. His native heart function did not recover and he experienced recurrent episodes of sustained ventricular tachycardia (VT) and electrical storm. He was evaluated for heart transplantation (OHT) and received a VT-ablation. However, he suffered an in-hospital cardiac arrest (IHCA) with subsequent implantation of an extracorporeal life support system (ECLS). After surgical placement of an Impella 5.5 due to left ventricular distension and pulmonary congestion, the ECLS was successfully weaned. He showed good neurological outcomes and underwent another high-risk VT-ablation. The patient was further stabilized under Impella 5.5 support in a bridge-to-transplant strategy. After 34 days he underwent a successful OHT.

DISCUSSION: In this interdisciplinary case report the surgically implanted Impella 5.5 as temporary mechanical circulatory support was used for multiple different indications and treatment strategies like ventricular unloading, haemodynamic support during high-risk interventions, and as bridge-to-transplant strategy in one patient.