PURPOSE: Evaluate the efficacy of ondansetron in preventing shivering after spinal anesthesia in cesarean delivery.
DESIGN: Systematic review and meta-analysis METHODS: Following the PRISMA statement, PubMed, CINAHL, Cochrane, EMBASE, Google scholar and other grey literature databases were searched for eligible studies.
FINDINGS: The overall incidence of shivering after spinal anesthesia in cesarean delivery is 32%, with 24% in patients who received ondansetron compared to 40% in the placebo group. A total of 19 trials consisting of 1399 patients were evaluated. Compared to placebo, ondansetron is effective in reducing the incidence of shivering (RR, 0.47; 95% CI, 0.29 to 0.78; P = 0.003). The quality of evidence is low due to substantial heterogeneity, imprecision and suspected publication bias. Patients who received ondansetron are less likely to require rescue treatment for shivering (RR, 0.34; 95% CI, 0.15 to 0.76; P = 0.009). Also, ondansetron is associated with a lower incidence of hypotension necessitating vasopressor treatment, and nausea and vomiting with no effects on the incidence of bradycardia.
CONCLUSION: Ondansetron is effective in mitigating shivering after spinal anesthesia in cesarean delivery.
DESIGN: Systematic review and meta-analysis METHODS: Following the PRISMA statement, PubMed, CINAHL, Cochrane, EMBASE, Google scholar and other grey literature databases were searched for eligible studies.
FINDINGS: The overall incidence of shivering after spinal anesthesia in cesarean delivery is 32%, with 24% in patients who received ondansetron compared to 40% in the placebo group. A total of 19 trials consisting of 1399 patients were evaluated. Compared to placebo, ondansetron is effective in reducing the incidence of shivering (RR, 0.47; 95% CI, 0.29 to 0.78; P = 0.003). The quality of evidence is low due to substantial heterogeneity, imprecision and suspected publication bias. Patients who received ondansetron are less likely to require rescue treatment for shivering (RR, 0.34; 95% CI, 0.15 to 0.76; P = 0.009). Also, ondansetron is associated with a lower incidence of hypotension necessitating vasopressor treatment, and nausea and vomiting with no effects on the incidence of bradycardia.