DOI 10.1021/acsabm.1c00202

Медицинская библиотека · ACS applied bio materials · 2021

Endothelium-Mimicking Nanomatrix Coating to Enhance Endothelialization after Left Atrial Appendage Closure Device Implantation.

Hwang Patrick T J, Sherwood Jennifer A, Millican Reid C, Bobba Pratheek S, Lynd Tyler O, Garner Joseph N, Brott Brigitta C, Hou Dongming, Jun Ho-Wook

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

Blood clots (90%) originate from the left atrial appendage (LAA) in non-valvular atrial fibrillation patients and are a major cause of embolic stroke. Long-term anticoagulation therapy has been used to prevent thrombus formation, but its use is limited in patients at a high risk for bleeding complications. Thus, left atrial appendage closure (LAAC) devices for LAA occlusion are well-established as an alternative to the anticoagulation therapy. However, the anticoagulation therapy is still required for at least 45 days post-implantation to bridge the time until complete LAA occlusion by neoendocardium coverage of the device. In this study, we applied an endothelium-mimicking nanomatrix to the LAAC device membrane for delivery of nitric oxide (NO) to enhance endothelialization, with the goal of possibly being able to reduce the duration of the anticoagulation therapy. The nanomatrix was uniformly coated on the LAAC device membranes and provided sustained release of NO for up to 1 month in vitro. In addition, the nanomatrix coating promoted endothelial cell proliferation and reduced platelet adhesion compared to the uncoated device membranes in vitro. The nanomatrix-coated and uncoated LAAC devices were then deployed in a canine LAA model for 22 days as a pilot study. All LAAC devices were not completely covered by neoendocardium 22 days post-implantation. However, histology image analysis showed that the nanomatrix-coated LAAC device had thicker neoendocardium coverage compared to the uncoated device. Therefore, our in vitro and in vivo results indicate that the nanomatrix coating has the potential to enhance endothelialization on the LAAC device membrane, which could improve patient outcomes by shortening the need for extended anticoagulation treatment.

Для цитирования: Hwang Patrick T J, Sherwood Jennifer A, Millican Reid C, Bobba Pratheek S, Lynd Tyler O, Garner Joseph N, Brott Brigitta C, Hou Dongming, Jun Ho-Wook. Endothelium-Mimicking Nanomatrix Coating to Enhance Endothelialization after Left Atrial Appendage Closure Device Implantation.. ACS applied bio materials. 2021. DOI: 10.1021/acsabm.1c00202.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.