m+Medelevator.RU
← Поиск публикаций
The British journal of radiology · 2026

Evaluation of patient setup accuracy using optical surface guidance in postoperative radiotherapy for patients with breast cancer after breast-conserving surgery.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wan Bao, Han Jiangtao, Zheng Yongtai, Liu Chao, Sun Shuo, Zhao Yu, Huan Fukui, Li Tantan

Аннотация

OBJECTIVES: To evaluate the clinical application of AlignRT surface-guided radiotherapy (SGRT) by quantifying interfractional setup errors in patients with breast-conserving surgery (BCS) stratified by the surgical side and use of thermoplastic immobilization masks.

METHODS: This prospective cohort study enrolled 125 patients with BCS treated at our center between January 2021 and June 2025. Patients were grouped by the surgical side (left/right) and immobilization method (with/without thermoplastic mask). After SGRT setup, cone-beam computed tomography (CBCT) was acquired for each fraction. Systematic and random errors were analyzed and 3-dimensional planning target volume (PTV) margins were calculated.

RESULTS: In total, 868 CBCT scans were obtained. With immobilization masks, left-sided patients exhibited significantly different setup errors from right-sided patients in the X (0.04 ± 0.25 cm vs. -0.05 ± 0.30 cm, P < .001) and Y (-0.09 ± 0.26 cm vs.0.02 ± 0.30 cm, P < .001) directions. Without immobilization masks, differences persisted in X (-0.05 ± 0.22 cm vs.0.01 ± 0.27 cm, P = .017) and Y (0.03 ± 0.23 cm vs.0.08 ± 0.27 cm, P = .039). Irrespective of the side, mask use significantly affected the errors in all 3 directions (all P < .05). The required PTV margins (cm) were: left BCS with mask (0.51, 0.51, 0.54), and without mask (0.47, 0.49, 0.57); right BCS with mask (0.64, 0.63, 0.55), and without mask (0.59, 0.62, 0.53).

CONCLUSIONS: In SGRT-based workflows for patients with BCS, omitting the thermoplastic mask improves setup reproducibility. Right-sided BCS cases require larger margins than left-sided cases.

ADVANCES IN KNOWLEDGE: This study provides clinical recommendations for patient positioning and immobilization techniques in whole-breast radiotherapy following breast-conserving surgery.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты