MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4244/eij-d-19-00901

Медицинская библиотека · EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2020

Treatment of Severe TRIcuspid Regurgitation in Patients with Advanced Heart Failure with CAval Vein Implantation of the Edwards Sapien XT VALve (TRICAVAL): a randomised controlled trial.

Dreger Henryk, Mattig Isabel, Hewing Bernd, Knebel Fabian, Lauten Alexander, Lembcke Alexander, Thoenes Martin, Roehle Robert, Stangl Verena, Landmesser Ulf, Grubitzsch Herko, Stangl Karl, Laule Michael

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

AIMS: The aim of our study was to compare the impact of implantation of a balloon-expandable transcatheter valve into the inferior vena cava (CAVI) on exercise capacity with optimal medical therapy (OMT) in patients with severe tricuspid regurgitation (TR) and high surgical risk.

METHODS AND

RESULTS

Twenty-eight patients were randomised to OMT (n=14) or CAVI (n=14). The primary endpoint was maximal oxygen uptake at the three-month follow-up. Secondary endpoints included six-minute walk test, NYHA class, NT-proBNP levels, right heart function, unscheduled heart failure hospitalisation, and quality of life as assessed by the Minnesota Living with Heart Failure Questionnaire (MLHFQ). Patients underwent follow-up examinations one, three, six, and twelve months after randomisation. Maximal oxygen uptake did not change significantly in either group after three months and there was no difference between the OMT and CAVI groups (-0.1±1.8 ml∙kg-1∙min-1 vs -1.0±1.6 ml∙kg-1∙min-1, p=0.4995). Compared to baseline, CAVI improved NYHA class, dyspnoea, and quality of life after three months. However, there were no statistically significant differences in the secondary endpoints between the groups. Four periprocedural complications occurred after CAVI, resulting in open heart surgery. Four patients in the OMT group and eight patients (including four after conversion to surgery) in the CAVI group died from right heart failure, sepsis or haemorrhage.

CONCLUSIONS

CAVI did not result in a superior functional outcome compared to OMT. Due to an unexpectedly high rate of valve dislocations, the study was stopped for safety reasons.

Для цитирования: Dreger Henryk, Mattig Isabel, Hewing Bernd, Knebel Fabian, Lauten Alexander, Lembcke Alexander, Thoenes Martin, Roehle Robert, Stangl Verena, Landmesser Ulf, Grubitzsch Herko, Stangl Karl, Laule Michael. Treatment of Severe TRIcuspid Regurgitation in Patients with Advanced Heart Failure with CAval Vein Implantation of the Edwards Sapien XT VALve (TRICAVAL): a randomised controlled trial.. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2020. DOI: 10.4244/eij-d-19-00901.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.