Extended aortic replacement in acute dissection by the separated elephant trunk technique.

Konishi T, Higuchi K, Fukata M, Takeda M, Akisima S, Fukuda S

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Extensive aortic replacement in acute dissection is currently not a widely accepted method of treatment.

METHODS

We developed a safe method for extended aortic repair including the aortic arch in type A acute dissection, and describe here its application in 5 cases. This method was based on a modification of the elephant trunk method and several other strategies. Most of the procedures were carried out under simple hypothermic circulatory arrest.

RESULTS

All patients recovered within 2 days without recurrent nerve injury. One patient suffered from unilateral upper arm palsy due to severe innominate dissection. Patients were all discharged and early postoperative computed tomography (CT) showed thrombotic obliteration around the elephant trunk. Follow-up CT after 4 to 18 months confirmed that thromboexclusion proceeded down to the distal end of the elephant graft in 1 patient and to the diaphragmatic level in 3 patients. Total obliteration was observed in the remaining 1 patient.

CONCLUSIONS

This technique enables extended aortic repair in acute dissection with no increase in morbidity, and effectively promotes thromboexclusion of the dissected lumen to a wider extent than conventional methods.

Для цитирования: Konishi T, Higuchi K, Fukata M, Takeda M, Akisima S, Fukuda S. Extended aortic replacement in acute dissection by the separated elephant trunk technique.. The Annals of thoracic surgery. 1999. DOI: 10.1016/s0003-4975(99)00304-5.