Ultrasound visualization of central slip injuries of the finger extensor mechanism.

Westerheide Edward, Failla Joseph M, van Holsbeeck Marnix, Ceulemans Ruth

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the ability of ultrasound to detect a central tear of the finger extensor tendon mechanism.

METHODS

Twelve fresh-frozen and thawed cadaver fingers were used. All fingers had a midradial incision with exposure of the extensor mechanism over the proximal interphalangeal joint. Six fingers had a sharp transection of the central slip. The other 6 fingers were used as sham dissection controls. All fingers had the exposure closed by suture and then were examined by a musculoskeletal ultrasonographer.

RESULTS

All 12 fingers were identified correctly as either sham controls with intact central slips or as injury models that had a transected central slip. Thus there was a sensitivity of 100% a specificity of 100%, and a positive predictive value of 1.000, which were statistically significant.

CONCLUSIONS

Diagnostic ultrasound is a very accurate noninvasive study that can identify central slip injuries in the extensor mechanism of the finger. We recommend that clinically suspected cases of boutonniere injury be scanned by high-frequency ultrasound to confirm the diagnosis and allow either early initiation of splinting or eliminate the need for prolonged splinting required for this injury.

Для цитирования: Westerheide Edward, Failla Joseph M, van Holsbeeck Marnix, Ceulemans Ruth. Ultrasound visualization of central slip injuries of the finger extensor mechanism.. The Journal of hand surgery. 2003. DOI: 10.1016/s0363-5023(03)00427-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.