Evaluation of High-Pitch Ungated Pediatric Cardiovascular Computed Tomography for the Assessment of Cardiac Structures in Neonates.

Sriharan Mona, Lazoura Olga, Pavitt Christopher W, Castellano Isabel, Owens Catherine M, Rubens Michael B, Padley Simon P G, Nicol Edward D

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: We evaluated a high-pitch, non-electrocardiogram-gated cardiac computed tomographic protocol, designed to image both cardiac and extracardiac structures, including coronary arteries, in a neonatal population (less than 1 year old) that was referred for congenital heart disease assessment and compared it with an optimized standard-pitch protocol in an equivalent cohort.

MATERIALS AND

METHODS

Twenty-nine high-pitch scans were compared with 31 age-matched, sex-matched, and weight-matched standard-pitch, dosimetrically equivalent scans. The visualization and subjective quality of both cardiac and extracardiac structures were scored by consensus between 2 trained blinded observers. Image noise, signal-to-noise and contrast-to-noise ratios, and radiation doses were also compared.

RESULTS

The high-pitch protocol better demonstrated the pulmonary veins (P=0.03) and all coronary segments (all P<0.05), except the distal right coronary artery (P=0.10), with no significant difference in the visualization of the remaining cardiac or extracardiac structures. Both contrast-to-noise and signal-to-noise ratios improved due to greater vessel opacity, with significantly fewer streak (P<0.01) and motion (P<0.01) artifacts. Image noise and computed tomographic dose index were comparable across the 2 techniques; however, the high-pitch acquisition resulted in a small, but statistically significant, increase in dose-length product [13.0 mGy.cm (9.0 to 17.3) vs. 11.0 mGy.cm (9.0 to 13.0), P=0.05] due to greater z-overscanning.

CONCLUSIONS

In neonates, a high-pitch protocol improves coronary artery and pulmonary vein delineation compared with the standard-pitch protocol, allowing a more comprehensive assessment of cardiovascular anatomy while obviating the need for either patient sedation or heart rate control.

Для цитирования: Sriharan Mona, Lazoura Olga, Pavitt Christopher W, Castellano Isabel, Owens Catherine M, Rubens Michael B, Padley Simon P G, Nicol Edward D. Evaluation of High-Pitch Ungated Pediatric Cardiovascular Computed Tomography for the Assessment of Cardiac Structures in Neonates.. Journal of thoracic imaging. 2016. DOI: 10.1097/rti.0000000000000201.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.