Cannulation strategy for aortic arch reconstruction using deep hypothermic circulatory arrest.

de Zélicourt Diane, Jung Philsub, Horner Marc, Pekkan Kerem, Kanter Kirk R, Yoganathan Ajit P

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

Aortic arch reconstruction in neonates is commonly performed using deep hypothermic circulatory arrest. However, concerns have arisen regarding potential adverse neurologic outcomes from this complex procedure, raising questions about the best arterial cannulation approach for cerebral perfusion and effective systemic hypothermia. In this study, we use computational fluid dynamics to investigate the effect of different cannulation strategies in neonates.

METHODS

We used a realistic template of a hypoplastic neonatal aorta as the base geometry to investigate four cannulation options: (1) right innominate artery, (2) innominate root, (3) patent ductus arteriosus (PDA), or (4) innominate root and PDA. Performance was evaluated according to the numerically predicted cerebral and systemic flow distributions compared with physiologic perfusion under neonatal conditions.

RESULTS

The four cannulation strategies were associated with different local hemodynamics; however, this did not translate into any significant effect on the measured flow distributions. The largest difference only represented 0.8% of the cardiac output and was measured in the innominate artery, which received 23.2% of the cardiac output in option 3 vs 24% in option 4. Pulmonary artery snaring benefited all systemic vessels uniformly.

CONCLUSIONS

Because of the very high vascular resistances in neonates, downstream vascular resistances dictated flow distribution to the different vascular beds rather than the cannulation strategy, allowing the surgical team to choose their method of preference. However, patients with aortic coarctation warrant further investigation and will most likely benefit from a 2-cannulae approach (option 4).

Для цитирования: de Zélicourt Diane, Jung Philsub, Horner Marc, Pekkan Kerem, Kanter Kirk R, Yoganathan Ajit P. Cannulation strategy for aortic arch reconstruction using deep hypothermic circulatory arrest.. The Annals of thoracic surgery. 2012. DOI: 10.1016/j.athoracsur.2012.03.053.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.