The Cleft palate-craniofacial journal : official publication of the American Cleft Palate-Craniofacial Association · 2019
A Pristine Approach for the Prominent Premaxilla in Bilateral Cleft Lip and Palate (BCLP) Cases.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Monga Nitika, Kharbanda Om P
Аннотация
OBJECTIVE: The neonate premaxilla in bilateral cleft lip and palate is often protruding and displaced laterally. Surgeons prefer the premaxilla to be repositioned and centralized to allow a tension-free primary lip repair. This report describes the fabrication of a premaxillary bonnet appliance with silicone material and its successful use in 2 cases of bilateral cleft lip and palate (BCLP).
PATIENTS, PARTICIPANTS: Two male BCLP patients of ages 34 days and 10 days, respectively.
INTERVENTIONS: Nonsurgical repositioning of the premaxillary segment using silicone cup-bonnet appliance.
RESULTS: The duration of active treatment by silicone appliance was 36 days in case 1 and 75 days in case 2. The retention period was 2 months and 3 months, respectively. The appliance made of room temperature vulcanizing (RTV) silicone is flexible and softer in comparison to the rigid conventional acrylic appliance and is therefore almost atraumatic. A gentler appliance resulted in enhanced compliance and acceptance by the neonates. There was a noticeable change in the position of the discernible asymmetric premaxilla. Analysis of frontal facial photographs revealed an angular change in the position of the premaxilla (C) by 12° in case 1 and 6° in case 2 in reference to the midfacial plane.
CONCLUSION: This silicone appliance provides enhanced compliance and improved retention compared to acrylic appliance since it is a more gentle, flexible, and less traumatic alternative to a rigid acrylic appliance. Further, the RTV silicone appliance can be 3-dimensionally printed for better accuracy following intraoral scanning and thus eliminating the need for impression making in cleft newborns.
PATIENTS, PARTICIPANTS: Two male BCLP patients of ages 34 days and 10 days, respectively.
INTERVENTIONS: Nonsurgical repositioning of the premaxillary segment using silicone cup-bonnet appliance.
RESULTS: The duration of active treatment by silicone appliance was 36 days in case 1 and 75 days in case 2. The retention period was 2 months and 3 months, respectively. The appliance made of room temperature vulcanizing (RTV) silicone is flexible and softer in comparison to the rigid conventional acrylic appliance and is therefore almost atraumatic. A gentler appliance resulted in enhanced compliance and acceptance by the neonates. There was a noticeable change in the position of the discernible asymmetric premaxilla. Analysis of frontal facial photographs revealed an angular change in the position of the premaxilla (C) by 12° in case 1 and 6° in case 2 in reference to the midfacial plane.
CONCLUSION: This silicone appliance provides enhanced compliance and improved retention compared to acrylic appliance since it is a more gentle, flexible, and less traumatic alternative to a rigid acrylic appliance. Further, the RTV silicone appliance can be 3-dimensionally printed for better accuracy following intraoral scanning and thus eliminating the need for impression making in cleft newborns.