Sensitivity and specificity of a urinary screening test used in an emergency setting to detect abnormal first trimester pregnancies.

Teixeira João L G, Rabaioli Paola, Savaris Ricardo F

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the performance of a commercial urinary test to screen for abnormal first trimester pregnancies in women presenting to an emergency room.

STUDY

DESIGN

In this prospective observational cohort, women with a confirmed first trimester pregnancy (gestational age <12 weeks) provided a urine sample for diagnosing the viability of their gestation. Pregnancy viability and location testing were confirmed by ultrasound and/or laparoscopy.

RESULTS

From 815 eligible patients for the study, 12 were excluded for not having a confirmed pregnancy (n = 6) or were lost to follow-up (n = 6). A total of 803 patients underwent testing and completed follow-up. The pretest probability of an abnormal pregnancy was 44% (9% for ectopic pregnancy and 35% for miscarriage). The test had the following parameters to identify an abnormal first-trimester pregnancy (sensitivity, 13%; 95% confidence interval [CI], 10-17; specificity, 82%; 95% CI, 78-86; positive predictive value, 36; 95% CI, 28-46; negative predictive value, 54; 95% CI, 50-58; accuracy, 47%; positive likelihood ratio, 0.74; 95% CI, 0.53-1.03; negative likelihood ratio, 1.06; 95% CI, 1-1.12). The reproducibility of the test in our study was high (kappa index between readers, 0.89; 95% CI, 0.77-1).

CONCLUSION

In our emergency setting, we were not able to confirm that the commercial test is adequate to detect or exclude an abnormal first-trimester pregnancy.

Для цитирования: Teixeira João L G, Rabaioli Paola, Savaris Ricardo F. Sensitivity and specificity of a urinary screening test used in an emergency setting to detect abnormal first trimester pregnancies.. American journal of obstetrics and gynecology. 2014. DOI: 10.1016/j.ajog.2014.06.056.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.