Clinica chimica acta; international journal of clinical chemistry · 2015
Clinical laboratory application of a reporter-gene assay for measurement of functional activity and neutralizing antibody response to infliximab.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Pavlov Igor Y, Carper James, Lázár-Molnár Eszter, Delgado Julio C
Аннотация
BACKGROUND: TNF-α antagonists such as infliximab are effective for the treatment of inflammatory bowel disease and other inflammatory and autoimmune diseases. Development of an immune response and subsequent neutralizing antibodies against these protein-based drugs is a major impediment that contributes to therapeutic failure, or adverse effects such as hypersensitivity reactions. As opposed to empirical dose-escalation strategies, rational and cost-effective evaluation of clinical non-responsiveness includes measurement of serum drug levels, and detection of drug-specific antibodies. We present the validation and 2-y experience using a functional, cell-based reporter gene assay (RGA) developed for measuring the biological activity and antibody response to serum infliximab.
METHODS: The RGA was used to test 4699 clinical specimens from patients suspected of therapeutic failure. In contrast to binding assays, which detect an overall antibody response, the RGA specifically detects those antibodies that have drug-neutralizing function, and thus, poses higher risk for therapeutic failure.
RESULTS: The RGA presented here is currently the only functional clinical test available to measure serum infliximab activity and neutralizing antibodies.
CONCLUSIONS: Due to its accuracy and precision, and suitability for high-throughput testing, this robust platform can be applied to any TNF-α antagonist, providing an invaluable tool for the clinical management of patients with treatment failure.
METHODS: The RGA was used to test 4699 clinical specimens from patients suspected of therapeutic failure. In contrast to binding assays, which detect an overall antibody response, the RGA specifically detects those antibodies that have drug-neutralizing function, and thus, poses higher risk for therapeutic failure.
RESULTS: The RGA presented here is currently the only functional clinical test available to measure serum infliximab activity and neutralizing antibodies.
CONCLUSIONS: Due to its accuracy and precision, and suitability for high-throughput testing, this robust platform can be applied to any TNF-α antagonist, providing an invaluable tool for the clinical management of patients with treatment failure.