m+Medelevator.RU
← Поиск публикаций
Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology · 2019

Motor Unit Number Index (MUNIX) as a biomarker of motor unit loss in post-polio syndrome versus needle EMG.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gawel Malgorzata, Zalewska Ewa, Szmidt-Salkowska Elżbieta, Lipowska Marta, Lusakowska Anna, Kaminska Anna M, Kostera-Pruszczyk Anna

Аннотация

UNLABELLED: MUNIX method (Motor Unit Number Index) had been not used to assess number of motor neurons in post-polio syndrome in contrary to needle electromyography.

OBJECTIVES: To confirm if MUNIX reflects motor unit loss and clinical stage and to assess difference in MUNIX and EMG results between muscles in different stage.

METHODS: 132 Muscles (MUNIX) and 96 (EMG) in 12 patients were studied and divided into groups: with normal strength(N), stable weakness and atrophy(S), new weakness and atrophy(W).

RESULTS: In PPS group MUNIX global was 561.36 ± 282.6 (right 6 muscles) and 561.27 ± 281.1 (left) significantly lower than in control group (six muscles 1139.6 ± 164.5) (p < 0.05). MUNIX global correlated with MRC global. MUNIX was greater in muscles with normal strength (95-100% of normal values) than in those with stable weakness (48%-0% of normal values) and new weakness (65%-0% of normal values). Respectively to clinical stage of muscle MUP (motor unit potential) amplitude increased to 350% of normal value, from 250% to 110%, and from 300% to 700%. No correlation was found between MUP parameters and MRC values.

CONCLUSIONS: MUNIX reflects motor dysfunction and could be a good biomarker for loss of motor neurons in PPS.

Предметные рубрики MeSH