MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0055462

Медицинская библиотека · PloS one · 2013

Improved cardiac MRI volume measurements in patients with tetralogy of Fallot by independent end-systolic and end-diastolic phase selection.

Freling Hendrik G, Pieper Petronella G, Vermeulen Karin M, van Swieten Jeroen M, Sijens Paul E, van Veldhuisen Dirk J, Willems Tineke P

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To investigate to what extent cardiac MRI derived measurements of right ventricular (RV) volumes using the left ventricular (LV) end-systolic and end-diastolic frame misrepresent RV end-systolic and end-diastolic volumes in patients with tetralogy of Fallot (ToF) and a right bundle branch block.

METHODS

Sixty-five cardiac MRI scans of patients with ToF and a right bundle branch block, and 50 cardiac MRI scans of control subjects were analyzed. RV volumes and function using the end-systolic and end-diastolic frame of the RV were compared to using the end-systolic and end-diastolic frame of the LV.

RESULTS

Timing of the RV end-systolic frame was delayed compared to the LV end-systolic frame in 94% of patients with ToF and in 50% of control subjects. RV end-systolic volume using the RV end-systolic instead of LV end-systolic frame was smaller in ToF (median -3.3 ml/m(2), interquartile range -1.9 to -5.6 ml/m(2); p<0.001) and close to unchanged in control subjects. Using the RV instead of LV end-systolic and end-diastolic frame hardly affected RV end-diastolic volumes in both groups and ejection fraction in control subjects (54±4%, both methods), while increasing ejection fraction from 45±7% to 48±7% for patients with ToF (p<0.001). QRS duration correlated positively with the changes in the RV end-systolic volume (p<0.001) and RV ejection fraction obtained in ToF patients when using the RV instead of the LV end-systolic and end-diastolic frame (p = 0.004).

CONCLUSION

For clinical decision making in ToF patients RV volumes derived from cardiac MRI should be measured in the end-systolic frame of the RV instead of the LV.

Для цитирования: Freling Hendrik G, Pieper Petronella G, Vermeulen Karin M, van Swieten Jeroen M, Sijens Paul E, van Veldhuisen Dirk J, Willems Tineke P. Improved cardiac MRI volume measurements in patients with tetralogy of Fallot by independent end-systolic and end-diastolic phase selection.. PloS one. 2013. DOI: 10.1371/journal.pone.0055462.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.