Duration of apnoea before start of backup ventilation during nCPAP in extremely preterm infants and time spent within the SpO2 target: a randomised cross-over study.

Ströbele Stephanie, Jung Tibor, Kraft Dominik, Forsteneichner Nadine, Mair Eva-Maria, Schiefele Lisa, Schmid Sebastian, Waitz Markus, Linhoff Vanessa, Westhoff Antje, Dreyhaupt Jens, Sohrabi Keywan, Ehrhardt Harald

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

Central apnoea due to immaturity of the respiratory drive constitutes the main cause of frequent and prolonged desaturations in extremely preterm (EPT) infants <28 weeks. We investigated the impact of varying the duration of apnoea before backup ventilation (BUV) on the measures of oxygenation in EPT infants during nasal continuous positive airway pressure (nCPAP) therapy.

DESIGN

Single-centre randomised cross-over trial.

SETTING

Level 3 neonatal intensive care unit.

PATIENTS: 24 EPT infants on nCPAP with BUV.

MAIN OUTCOME MEASURES: The primary outcome was the time spent within a predefined oxygen saturation (SpO2) target (88%-95% or ≥88% with fraction of inspired oxygen (FiO2) =0.21) during start of BUV after 4 s of apnoea duration (AD 4) or 16 s of apnoea duration (AD 16)

RESULTS

The study was successfully completed in 22 children (median gestational age 24+5 weeks, birth weight 628 g, postnatal age 48 days). Mean time spent within the SpO2 target didn't differ between AD 4 and AD 16 (66.9% vs 67.2%, p=0.88). There were no differences in the time below or above the SpO2 target, prolonged (>30 s, >60 s, >120 s) and severe (<80%, <70%) episodes of hypoxaemias and cerebral tissue oxygenation. Mean FiO2, mean airway pressure, transcutaneous carbon dioxide pressure, heart rate and respiratory frequency did not differ while the rate of BUV was significantly higher during AD 4.

CONCLUSION

Reducing the time of apnoea until start of BUV didn't improve the time spent within the SpO2 target in respiratory unstable EPT infants. Our data demand intensified efforts to specify these settings of non-invasive respiratory support that better achieve this important clinical goal.

TRIAL REGISTRATION NUMBER: DRKS00031911.

Для цитирования: Ströbele Stephanie, Jung Tibor, Kraft Dominik, Forsteneichner Nadine, Mair Eva-Maria, Schiefele Lisa, Schmid Sebastian, Waitz Markus, Linhoff Vanessa, Westhoff Antje, Dreyhaupt Jens, Sohrabi Keywan, Ehrhardt Harald. Duration of apnoea before start of backup ventilation during nCPAP in extremely preterm infants and time spent within the SpO2 target: a randomised cross-over study.. Archives of disease in childhood. Fetal and neonatal edition. 2026. DOI: 10.1136/archdischild-2025-328734.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.