[Analysis of 18 polycyclic aromatic hydrocarbons in water by solid phase extraction with gas chromatography-triple quadrupole mass spectrometry].
Аннотация
OBJECTIVE
To establish a method for analysis of polycyclic aromatic hydrocarbons( PAHs) in water by solid extraction column with GC-MS/MS.
METHODS
The extraction effects of columns, such as Oasis HLB, C_(18), Oasis MCX and Oasis MAX, were compared. The influence of different kinds of solid phase extraction columns for the PAHs and method ology study were investigated. The samples were extracted by preactivated C_(18) column, eluted by dichloromethane, detected by gas chromatography-triple quadrupole mass spectrometry.
RESULTS
Under the established optimal test condition, the recoveries of PAHs were 78%-130%, the RSD were 0. 8%-5. 0%, the limit of quantitation were in the range of 0. 0007-0. 0199 μg/L.
CONCLUSION
The method is fast and easy, it can meet the requirement for analytical measurement of various PAHs in water.