MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1995-7645(13)60161-3

Медицинская библиотека · Asian Pacific journal of tropical medicine · 2013

Application of internal fixation of steel-wire limited loop in early Achilles tendon rupture.

Chen Zhe, Wei Jia-Sen, Hou Zhao-Yang, Hu Jiong, Cao Yan-Guang, Chen Qi-Xin

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To explore the clinical effect and safety of internal fixation of steel-wire limited loop in early Achilles tendon rupture.

METHODS

Seventy-six patients respectively with early transected and avulsed types of Achilles tendon rupture were selected and treated with internal fixation of steel-wire limited loop. The patients began to take exercise for their lower limbs through continous passive motion as early as possible after surgical repair, and the loops were removed after 3-5 months. Six months later, the condition of complications including Achilles tendon re-rupture, wound fistula, wound infection and skin necrosis, cutaneous sensation in sural nerve dominance region, time back to preinjury work or learning as well as time to physical activities were observed. One year later, the therapeutic effect was evaluated, and the maximum circumferences of bilateral legs and ruptured plane circumferences of Achilles tendon were measured.

RESULTS

The wound of all patients healed well, no complications like Achilles tendon re-rupture, wound fistula, wound infection and skin necrosis occured, and the cutaneous sensation in sural nerve dominance region was normal. The mean time back to preinjury work or learning as well as to pysical activities of all patients were respectively 10 and 22 weeks. Seventy out of 76 patients (92.1%) achieved an excellent effect, and 6 (7.9%) good effect. The excellent and good rate came up to 100%. The maximum circumference in the affected leg decreased to 2 mm averagely compared with the offside, while the ruptured plane circumferences of Achilles tendon in the affected side increased to 2.2 mm compared with the offside.

CONCLUSIONS

For early Achilles tendon rupture, internal fixation of steel-wire limited loop can recover the ankle function better, return to the preinjury state in the shortest time, and has few complications.

Для цитирования: Chen Zhe, Wei Jia-Sen, Hou Zhao-Yang, Hu Jiong, Cao Yan-Guang, Chen Qi-Xin. Application of internal fixation of steel-wire limited loop in early Achilles tendon rupture.. Asian Pacific journal of tropical medicine. 2013. DOI: 10.1016/s1995-7645(13)60161-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.