MedElevator Войти в исследования
← Поиск публикаций

DOI 10.22575/interventionalradiology.2024-0030

Медицинская библиотека · Interventional radiology (Higashimatsuyama-shi (Japan) · 2024

Combining Cutting and Drug-eluting Balloon for Resistant Arteriovenous Fistula Stenosis (CONCERTO)-A Pilot Study.

Zhuang Kun Da, Wei Mark Wang Qi, Min Shaun Xavier Chan Ju, Gogna Apoorva, Venkatanarasimha Nanda, Patel Ankur, Er Jasmine Chua Ming, Irani Farah Gillan, Leong Sum, Too Chow Wei, Chandramohan Sivanathan, Tay Kiang Hiong, Tan Bien Soo

СтатьяПеревод в очереди

Аннотация

Purpose: To evaluate the feasibility and preliminary evidence of the efficacy of combined cutting balloon and drug-coated balloon angioplasty for the treatment of arteriovenous fistula stenoses resistant to conventional balloon angioplasty. Material and

Methods

From August 2018 to January 2019, 19 patients (mean age = 64.9 ± 8.6 years; males = 63%) with resistant arteriovenous fistula stenosis, defined as >30% residual stenosis after conventional balloon angioplasty, were enrolled into this single-center prospective pilot study. The resistant arteriovenous fistula stenoses were treated with a cutting balloon followed by a drug-coated balloon. The primary outcome measure was 6-month target lesion patency.

Results

The degree of residual stenosis after conventional balloon angioplasty was 48.8 ± 11.3%, decreasing to 18.7 ± 10.4% after combined cutting and drug-coated balloon angioplasty. Technical success, defined as < 30% residual stenosis, was achieved in 94.7% (18 of 19 stenoses). The 6-month target lesion patency was 100%, while the 6-month access circuit primary patency was 94.7% (n = 18/19) due to recurrent non-target lesion stenosis. No venous rupture or major complication was encountered.

Conclusions

This pilot study provides evidence to support the conduct of a phase 3 randomized clinical trial to prove the superiority of a cutting balloon and drug-coated balloon combination for resistant arteriovenous fistula stenoses.

Для цитирования: Zhuang Kun Da, Wei Mark Wang Qi, Min Shaun Xavier Chan Ju, Gogna Apoorva, Venkatanarasimha Nanda, Patel Ankur, Er Jasmine Chua Ming, Irani Farah Gillan, Leong Sum, Too Chow Wei, Chandramohan Sivanathan, Tay Kiang Hiong, Tan Bien Soo. Combining Cutting and Drug-eluting Balloon for Resistant Arteriovenous Fistula Stenosis (CONCERTO)-A Pilot Study.. Interventional radiology (Higashimatsuyama-shi (Japan). 2024. DOI: 10.22575/interventionalradiology.2024-0030.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.