m+Medelevator.RU
← Поиск публикаций
BJOG : an international journal of obstetrics and gynaecology · 2004

Three-dimensional ultrasonographic assessment of fetal lung volume as prognostic factor in isolated congenital diaphragmatic hernia.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ruano Rodrigo, Benachi Alexandra, Joubin Laurence, Aubry Marie-Cécile, Thalabard Jean-Christophe, Dumez Yves, Dommergues Marc

Аннотация

OBJECTIVE: To evaluate the potential of three-dimensional ultrasound to predict outcome in congenital diaphragmatic hernia.

DESIGN: Prospective observational study.

SETTING: Tertiary care centre.

POPULATION: Twelve cases of isolated congenital diaphragmatic hernia (11 left-sided, 1 right-sided) and 109 controls.

METHODS: Fetal lung volume was assessed by three-dimensional ultrasound using the technique of rotation of the multiplanar imaging. In the control fetuses, a logistic transformation was performed to correlate fetal lung volume with gestational age, and the confidence interval was obtained with a bootstrap resampling. A mathematical equation was then obtained allowing calculation of the expected fetal lung volume as a function of gestational age. In fetuses with congenital diaphragmatic hernia, the observed/expected lung volume ratio was compared with postnatal outcome.

MAIN OUTCOME MEASURES: Neonatal mortality and pulmonary hypoplasia, which was defined as lung/body weight ratios less than 0.012.

RESULTS: The expected fetal lung volume was derived from the mathematical equation: Fetal lung volume (mL) = exp (4.72/(1 + exp ((20.32 - gestational age in weeks)/6.05))). The observed/expected fetal lung volume ratio was significantly lower in the congenital diaphragmatic hernia group (median: 0.34, range: 0.16-0.66), than in the control group (median: 1.02, range: 0.62-1.97, P < 0.0001). The distribution of this ratio was significantly downshifted in the infants with congenital diaphragmatic hernia who died (median: 0.19, range: 0.18-0.66) compared with survivors (median: 0.44, range: 0.36-0.66, P= 0.04). The observed/expected fetal lung volume ratio was also correlated with the postmortem lung/body weight ratio.

CONCLUSION: In isolated congenital diaphragmatic hernia, fetal lung volume measurement by three-dimensional ultrasound is a potential predictor for pulmonary hypoplasia and postnatal outcome.