Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2015

Assessment of liver fibrosis in rats by MRI with apparent diffusion coefficient and T1 relaxation time in the rotating frame.

Hu Genwen, Zhang Xuhui, Liang Wen, Zhong Xing, Chan Queenie, Lin Xiaoying, Lin Ting, Li Yufa, Quan Xianyue

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To explore the value of T1 relaxation times in the rotating frame (T1 ρ or T1 rho) for evaluating liver fibrosis stage, compared to apparent diffusion coefficients (ADCs).

MATERIALS AND

METHODS

Liver fibrosis in model rats (n = 50) was produced by carbon tetrachloride (CCl4 ) injection. Five rats died during the experiment. Surviving model rats (n = 45) and controls (n = 15) were subjected to 3.0T MRI and the ADCs (b-values: 0, 800 s/mm(2) ) and T1 ρ values were determined. Liver fibrosis stage (F0-F4) was defined based on METAVIR scoring. Nonparametric statistical methods and receiver operating characteristic (ROC) curve analyses were employed to determine diagnostic accuracy.

RESULTS

Mean ADC and T1 ρ associated negatively (r = -0.732 P < 0.001) and positively (r = 0.863 P < 0.001), respectively, with severity of fibrosis stage. Analysis of ROC curves for fibrosis staging showed that the area under the curve (AUC) for T1 ρ (stage F0 vs. F1-F4 = 0.976, stage F0-F1 vs. F2-F4 = 0.920, stage F0-F2 vs. F3-F4 = 0.938, and stage F0-F3 vs. F4 = 0.931) was larger than that for ADCs (0.917, 0.924, 0.842, and 0.781, respectively).

CONCLUSION

ADC and T1 ρ values correlate with liver fibrosis stage. The performance of the T1 ρ parameter was superior to that of the ADC parameter in the differentiation of liver fibrosis stages in a CCl4 rat model.

Для цитирования: Hu Genwen, Zhang Xuhui, Liang Wen, Zhong Xing, Chan Queenie, Lin Xiaoying, Lin Ting, Li Yufa, Quan Xianyue. Assessment of liver fibrosis in rats by MRI with apparent diffusion coefficient and T1 relaxation time in the rotating frame.. Journal of magnetic resonance imaging : JMRI. 2015. DOI: 10.1002/jmri.25084.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.