MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0002-9149(02)02666-8

Медицинская библиотека · The American journal of cardiology · 2002

Measurement of coronary flow reserve in the anterior and posterior descending coronary arteries by transthoracic Doppler ultrasound.

Voci Paolo, Pizzuto Francesco, Mariano Enrica, Puddu Paolo Emilio, Chiavari Pier Andrea, Romeo Francesco

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

We describe for the first time transthoracic Doppler ultrasound assessment of coronary flow reserve (CFR) in both the posterior descending (PDA) and left anterior descending (LAD) coronary arteries. CFR (hyperemic/resting diastolic flow velocity ratio) was measured by 90-second intravenous adenosine infusion (140 microg/kg/min). Baseline PDA flow was detected in 62 of 81 subjects (76%), and the CFR was measurable in 44 of them (54%) because of adenosine-induced hyperventilation. According to angiography, these 44 subjects were divided into 3 groups: group 1 (0% to 29% stenosis), group 2 (30% to 69% stenosis), and group 3 (> or =70% stenosis). PDA CFR was 2.62 +/- 0.25 in 17 patients in group 1, 2.33 +/- 0.32 in 9 patients in group 2, and 1.40 +/- 0.54 in 18 patients in group 3 (F = 41.83, p <0.0001). LAD CFR was 3.31 +/- 0.54 in 15 patients in group 1, 2.49 +/- 0.71 in 10 patients in group 2, and 1.12 +/- 0.49 in 19 patients in group 3 (F = 65.68, p <0.0001). A cut-off of <2 identified > or =70% stenosis in both of the arteries supplying the PDA and in the LAD. Noninvasive measurement of PDA CFR is feasible and may improve with technologic advancement and the use of selective adenosine receptor agonists, thus preventing hyperventilation.

Для цитирования: Voci Paolo, Pizzuto Francesco, Mariano Enrica, Puddu Paolo Emilio, Chiavari Pier Andrea, Romeo Francesco. Measurement of coronary flow reserve in the anterior and posterior descending coronary arteries by transthoracic Doppler ultrasound.. The American journal of cardiology. 2002. DOI: 10.1016/s0002-9149(02)02666-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.