MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5114/ait.2020.101387

Медицинская библиотека · Anaesthesiology intensive therapy · 2020

Comparison of the Parker flex tip and the unoflex reinforced endotracheal tube for orotracheal fibreoptic intubation in simulated difficult intubation patients.

Narhari Rupesh, Nazaruddin Wan Hassan Wan Mohd, Mohamad Zaini Rhendra Hardy, Che Omar Sanihah, Abdullah Nik Mohamad Nik, Seevaunnamtum Praveena

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

The choice of endotracheal tube (ETT) is important for successful orotracheal fibreoptic intubation (OFI). The aim of this study was to compare the use of the Parker flex tip (PFT) with the unoflex reinforced (UFR) ETT during OFI.

MATERIAL AND

METHODS

A total of 58 patients who underwent elective surgery under general anaesthesia were randomised to two ETT groups, the PFT group (n = 29) and the UFR group (n = 29), for OFI in simulated difficult intubation patients using a rigid cervical collar. After successful standardised induction and relaxation, OFI and railroading of selected ETT were subsequently performed by a similarly experienced practitioner. Ease of insertion, degree of manipulation, time to successful intubation, post-intubation complications and haemodynamic changes were recorded for both groups.

RESULTS

he percentage of easy intubation was comparable between both groups with a slightly higher percentage in the UFR group than the PFT group (69.0% vs. 62.0%; P = 0.599). Degree of manipulation was also comparable between the two groups; the percentage of cases in which manipulation was not required was slightly higher in the UFR group than the PFT group (69.0% vs. 62.1%; P = 0.849). Time to successful intubation was also comparable between the groups, although the time was slightly shorter for the UFR group than the PFT group (56.9 s ± 39.7 s vs. 63.9 s ± 36.9 s; P = 0.488). There were also no significant differences in other parameters.

CONCLUSIONS

The Parker flex tip ETT was comparable to the unoflex reinforced ETT for OFI in simulated difficult airway patients.

Для цитирования: Narhari Rupesh, Nazaruddin Wan Hassan Wan Mohd, Mohamad Zaini Rhendra Hardy, Che Omar Sanihah, Abdullah Nik Mohamad Nik, Seevaunnamtum Praveena. Comparison of the Parker flex tip and the unoflex reinforced endotracheal tube for orotracheal fibreoptic intubation in simulated difficult intubation patients.. Anaesthesiology intensive therapy. 2020. DOI: 10.5114/ait.2020.101387.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.