The use of a CircuLite micro-pump for congenitally corrected transposition of the great arteries.

Jacobs Steven, Rega Filip, Burkhoff Daniel, Meyns Bart

Клинический случайСтатьяПеревод в очереди

Аннотация

We report a case of a 49-year old male with a congenitally corrected transposition of the great arteries (ccTGA) implanted with a left atrial to right subclavian artery ventricular assist device (CircuLite) because of the failure of the anatomic right (systemic) ventricle. Additionally, elevated pulmonary pressures and peripheral vascular resistance (7.4 Wood units) prevented him from being put on the transplant list. The implant, performed off-pump through a right minithoracotomy, was uncomplicated and there were no adverse events. Within 1 month of the implant, there was a marked improvement in exercise tolerance and decreases in pulmonary pressures and resistance, so that the patient was able to return to work and became eligible for transplant listing. As of the time of writing, the patient has been supported for 10 months and is awaiting a heart transplant.

Для цитирования: Jacobs Steven, Rega Filip, Burkhoff Daniel, Meyns Bart. The use of a CircuLite micro-pump for congenitally corrected transposition of the great arteries.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2012. DOI: 10.1093/ejcts/ezs308.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.