m+Medelevator.RU
← Поиск публикаций
Therapeutic advances in respiratory disease · 2024

A multicenter observational study assessing the safety, feasibility, and complications of Bonastent in central airway obstruction.

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Madisi Nagendra Y, Ali Sana, Greenberg Daniel, Kobbari Gowthami, Salick Muhammad, Parimi Anoosh, Boujaoude Ziad, Abouzgheib Wissam

Аннотация

BACKGROUND: Self-expandable metallic stents (SEMS) are increasingly used in the management of both malignant and nonmalignant airway stenosis. There are multiple stents available in the market; however, the current literature on the efficacy and safety of newly available 3rd generation SEMS (Bonastent) is extremely limited and only has data from single center studies.

OBJECTIVES: To report the efficacy and early (<7 days) and late (⩾7 days) complications in patients with central airway obstruction (CAO) treated with Bonastent placement at two institutions.

DESIGN: We performed a retrospective analysis of data of consecutive patients who underwent therapeutic bronchoscopy and Bonastent placement at two tertiary care university hospitals between January 2019 and November 2023.

METHODS: Bonastent deployment was performed in the operating room. Stents were deployed using rigid or flexible bronchoscopy under direct visualization with a flexible bronchoscope and in conjunction with fluoroscopic guidance. We then analyzed the effectiveness, short-term, and long-term complications of Bonastent placement.

RESULTS: A total of 107 Bonastents® were placed in 96 patients. The most common etiology of CAO was malignancy, 92.7% (n = 89), followed by excessive dynamic airway collapse (EDAC) and post-intubation tracheal stenosis. Seventy-three patients (76%) had improvement in symptoms or imaging within 7 days of stent placement, including successful liberation from mechanical ventilation in a patient with CAO. Early complications occurred in seven patients (two-airway bleeding, two-mucus plugging that improved with airway clearance, two-stent migrations, and one-cough).Late complications occurred in 23 patients (1-stent migration requiring revision bronchoscopy and replacement of airway stent, 11-mucus plugging, 6-granulation tissue, 2-pneumonia, 1-cough, 1-tumor ingrowth/stent fracture, 1-airway emergency due to excessive granulation tissue obstructing the distal end of the stent and had a failed cricothyroidotomy leading to death). Overall, the early complication rate was 7.3% (7/96) and late complication rate was 23.9% (23/96).

CONCLUSION: Our study is the first multicenter study that found a good safety profile with a low complication rate after tracheobronchial Bonastent placement with improvement in symptoms soon after stent placement.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты