OBJECTIVE

To evaluate whether the conventional autologous fascial (AF) sling is superior or equal to the readjustable transobturator (TOT) sling in efficacy and safety in women with stress urinary incontinence (SUI).

STUDY

DESIGN

This was a retrospective study comprised of a sample of 463 patients from 2003 to 2009. A total of 203 women received TOT slings for urodynamically confirmed SUI, and 260 patients received AF slings. We analyzed the subjective success rate (cure and/or improvement) after 12 and 24 months of surgery as well as any immediate and late surgical complications.

RESULTS

Both groups were statistically similar with regard to age, parity, body mass index, number of previous gynecological surgeries, and antiincontinence therapies. After 12 months patients with the TOT sling had a higher subjective percentage efficacy rate when compared to those with the AF sling (94% vs. 88%, p < 0.05); however, after 24 months this percentage was no longer statistically significant (88.7% vs. 84.6%, p = 0.20). The TOT sling presented fewer postoperative complication rates (14.1% vs. 25.6%, p < 0.05), similar intraoperative complication rates (1.15% vs. 2.3%, p = 0.22) and a shorter mean operative time (23 vs. 112 minutes, p < 0.05) than the AF sling.

CONCLUSION

Both techniques had similar subjective efficacy rates, but the TOT sling demonstrated fewer postoperative surgical complications than the AF sling.

Для цитирования: Brito Luiz Gustavo Oliveira, Rodrigues Heitor Leandro Paiva, Carvalho Maria Angela Cury Ramos, Magnani Pedro Sérgio, Lopes Alessandro Henrique Antunes, Sabino-de-Freitas Maurício Mesquita. Comparison of the efficacy and safety of surgical procedures utilizing autologous fascial and transobturator slings in patients with stress urinary incontinence.. The Journal of reproductive medicine. 2013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.