DOI 10.1016/s1010-7940(98)00087-6
Thoracic computed tomography prior to redo coronary surgery.
Аннотация
OBJECTIVE
Median resternotomy in coronary redo surgery represents a specific risk for injury of adjacent retrosternal structures. Aiming at improved preoperative evaluation of retrosternal structures, computed tomography (CT) techniques were routinely applied in redo cases.
METHODS
Of 99 patients undergoing coronary reoperations since April 93, thoracic CT scans were retrospectively analyzed for retrosternal vicinity of cardiovascular structures, condition of the ascending aorta and structural abnormalities of the sternum.
RESULTS
The minimal median distance between the posterior sternum surface and the anterior aortic wall was measured at 1.9 +/- 0.9 cm, whereas the mean closest distance to the anterior right ventricular wall was 0.4 +/- 0.5 cm. In 28 cases, the distance between sternum and aorta was smaller than or equal to 1 cm. No measurable distance between the sternum and the right ventricle was noted in 41 patients. Calcification of the ascending aorta became obvious 56 times. With respect to potential injury of the ascending aorta or the right ventricle, a safe reentry by resternotomy was facilitated in all cases. However, following complete sawing, the innominate vein became injured during retrosternal dissection in two cases. Preventive femoral vessel exposure was not performed and urgent femoral cannulation (n = 1) was infrequent.
CONCLUSIONS
Thoracic CT scanning prior to redo coronary surgery allows for detailed assessment of retrosternal relations and facilitates reopening of the sternum. Preventive femoral vessel exposure and lateral thoracotomies may be avoidable in many cases.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.