MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/ijerph191912052

Медицинская библиотека · International journal of environmental research and public health · 2022

Determination of Carbonyl Compounds in Different Work Environments: Comparison between LC-UV/DAD and LC-MS/MS Detection Methods.

Castellani Federica, Antonucci Arianna, Pindinello Ivano, Protano Carmela, Vitali Matteo

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

There were two analytical methods for the determination of 12 carbonyl compounds (CCs) by using liquid chromatography (LC) coupled with mass spectrometry (MS/MS) and diode array detector (UV/DAD) that were developed and applied to 52 samples that were collected in 10 workplaces. Linearity (0.996 < R2 < 0.999), intra-day repeatability (0.7 < RSD% < 10), and inter-day repeatability (5 < RSD% < 16) were acceptable for both techniques, but the highest sensibility of the MS/MS method allowed us to correctly quantify 98% of the samples (versus 32% by UV/DAD). The comparison of the concentrations that were obtained by quantifying the same sample with both techniques showed good agreement for acetaldehyde and formaldehyde (0.1 < % deviation < 30) but much higher for the less abundant congeners. In real samples, formaldehyde was the most abundant congener (concentrations between 2.7 and 77 µg m-3), followed by acetaldehyde (concentrations between 1.5 and 79 µg m-3) and butyraldehyde (concentrations between 0.4 and 13 µg m-3). In all the beauty salon samples, instead, the most abundant congener was acetaldehyde (concentrations between 19 and 79 µg m-3), probably associated with the use of beauty products. Principal components analysis (PCA) confirms the ubiquitous character of formaldehyde and highlights the influence of minority CCs on different workplaces.

Для цитирования: Castellani Federica, Antonucci Arianna, Pindinello Ivano, Protano Carmela, Vitali Matteo. Determination of Carbonyl Compounds in Different Work Environments: Comparison between LC-UV/DAD and LC-MS/MS Detection Methods.. International journal of environmental research and public health. 2022. DOI: 10.3390/ijerph191912052.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.