The Light and the Dark of Early and Intermediate AMD: Cone- and Rod-Mediated Changes Are Linked to Fundus Photograph and FAF Abnormalities.
Аннотация
PURPOSE: The purpose of this paper is to describe the extent to which scotopic and photopic measures of visual function predict color fundus photograph (CFP) and fundus autofluorescence (FAF) changes in early and intermediate nonexudative AMD.
METHODS
Sixty-nine observers were recruited: 56 AMD patients (mean age, 73 ± 12.98 years) and 13 controls (mean age, 67.77 ± 9.72 years). A nonmydriatic retinal camera was used to obtain stereo fundus photographs and FAF images were recorded with a cSLO Heidelberg Spectralis HRA+OCT. Visual acuity (VA) was measured using an Early Treatment of Diabetic Retinopathy Study chart. Contrast sensitivity (CS) was assessed with a Pelli-Robson chart. Dark adaptation (DA) curves were recorded at 3° eccentricity using a PC-based technique. Analysis of these curves yielded five parameters: cone threshold (CT), cone time constant (CC), cone-rod break (α), slope of the second rod component (S2), and rod-rod break (β).
RESULTS
Both cone and rod sensitivity recovery were grossly abnormal in the patients. The rod recovery slope (S2) most accurately predicted the fundus photograph-based grade and the FAF classification (ρ = 0.61 and ρ = 0.60, respectively; both P < 0.0001). CS showed a strong association with FAF (ρ = 0.50, P < 0.0001) and with fundus photograph-based grade (ρ = 0.38, P < 0.002). There was no correlation between VA and either imaging method.
CONCLUSIONS
Dynamic, rod-based measures most accurately reflect the severity of early AMD. Although less specific to AMD than DA changes, static photopic abnormalities such as CS also correspond with morphologic changes. Assessment of function in early AMD should include dynamic rod- and cone-mediated measurements of sensitivity recovery.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.