m+Medelevator.RU
← Поиск публикаций
Advances in respiratory medicine · 2021

Prognostic significance of lung diffusion capacity and spirometric parameters in relation to hemodynamic status in heart transplant candidates.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mohammadi Somaye, Ansari Ramandi Mohammad Mostafa, Safaei Ali, Mirdamadi Mahsa, Taghavi Sepideh, Amin Ahmad, Naderi Nasim

Аннотация

INTRODUCTION: Investigations have described a correlation between the severity of heart failure and the severity of pulmonary function abnormalities. In this study, we investigated the association of resting spirometric parameters, lung diffusion for carbon monoxide (DLCO), and the transfer coefficient (KCO) with hemodynamic variables and outcomes in a cohort of heart transplant candidates.

MATERIAL AND METHODS: Between January 2018 and January 2020, a total of 100 patients with advanced heart failure who were scheduled for right heart catheterization (RHC) as a pre-transplant evaluation measure were enrolled. Spirometry and DLCO were performed in all patients within 24 hours of their RHC. All selected patients were followed for a median (IQR) time of 6 (2-12) months. The end points of interest were heart failure-related mortality and a combined event involving HF-related mortality, heart transplantation (HTX), and need for the placement of a left ventricular assist device (LVAD).

RESULTS: Among 846 patients scheduled for RHC, a total of 100 patients (25% female) with a mean (SD) age of 38.5 (12.8) were enrolled. There was a significant correlation between FEV1/FVC and CVP (r = -0.22, p = 0.02), PCWP (r = -0.4, p < 0.001), mPAP (r = -0.45, p < 0.001), and PVR (r = -0.32, p = 0.001). The cardiac output correlated with DLCO (r = 0.3, p = 0.008). Spirometry parameters, DLCO parameters, and hemodynamic parameters did not correlate with the combined event. Among the several variables, only PVR had an independent association with the combined event.

CONCLUSION: Both mechanical and gas diffusion parameters of the lung were not associated with outcomes in the homogeneous group of heart transplant candidates.