MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2015.09.051

Медицинская библиотека · Biosensors & bioelectronics · 2015

Ultrasensitive photoelectrochemical immunoassay for CA19-9 detection based on CdSe@ZnS quantum dots sensitized TiO2NWs/Au hybrid structure amplified by quenching effect of Ab2@V(2+) conjugates.

Zhu Hua, Fan Gao-Chao, Abdel-Halim E S, Zhang Jian-Rong, Zhu Jun-Jie

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A novel, enhanced photoelectrochemical immunoassay was established for sensitive and specific detection of carbohydrate antigen 19-9 (CA19-9, Ag). In this protocol, TiO2 nanowires (TiO2NWs) were first decorated with Au nanoparticles to form TiO2NWs/Au hybrid structure, and then coated with CdSe@ZnS quantum dots (QDs) via the layer-by-layer method, producing TiO2NWs/Au/CdSe@ZnS sensitized structure, which was employed as the photoelectrochemical matrix to immobilize capture CA19-9 antibodies (Ab1); whereas, bipyridinium (V(2+)) molecules were labeled on signal CA19-9 antibodies (Ab2) to form Ab2@V(2+) conjugates, which were used as signal amplification elements. The TiO2NWs/Au/CdSe@ZnS sensitized structure could adequately absorb light energy and dramatically depress electron-hole recombination, resulting in evidently enhanced photocurrent intensity of the immunosensing electrode. While target Ag were detected, the Ab2@V(2+) conjugates could significantly decrease the photocurrent detection signal because of strong electron-withdrawing property of V(2+) coupled with evident steric hindrance of Ab2. Thanks to synergy effect of TiO2NWs/Au/CdSe@ZnS sensitized structure and quenching effect of Ab2@V(2+) conjugates, the well-established photoelectrochemical immunoassay exhibited a low detection limit of 0.0039 U/mL with a wide linear range from 0.01 U/mL to 200 U/mL for target Ag detection. This proposed photoelectrochemical protocol also showed good reproducibility, specificity and stability, and might be applied to detect other important biomarkers.

Для цитирования: Zhu Hua, Fan Gao-Chao, Abdel-Halim E S, Zhang Jian-Rong, Zhu Jun-Jie. Ultrasensitive photoelectrochemical immunoassay for CA19-9 detection based on CdSe@ZnS quantum dots sensitized TiO2NWs/Au hybrid structure amplified by quenching effect of Ab2@V(2+) conjugates.. Biosensors & bioelectronics. 2015. DOI: 10.1016/j.bios.2015.09.051.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.