Evaluation of the safety and effectiveness of a sealant hemostatic patch for preventing cerebrospinal fluid leaks in cranial surgery.

Sánchez Fernández Carlos, Rodríguez-Arias Carlos Alberto

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Cerebrospinal fluid (CSF) leak remains a significant source of morbidity after neurosurgical procedures. The objective is to evaluate the effectiveness and safety of a polyethylene glycol-coated collagen patch (PCC) in different neurosurgical procedures.

METHODS

A retrospective, single-center cohort study in patients who underwent a cranial neurosurgical procedure. After collecting multiple data variables, patients were divided into two groups depending on the use of PCC as sealant on dural closure following procedures.

RESULTS

Data from 230 patients were collected (PCC, 128; control group, 102). Incidence of CSF leakage was significantly lower in the PCC group (p < .001). Complications that were significantly lower in PCC than the control group included surgical infection (p = .022), and hydrocephalus (p = .017), as well as reduced rates of reintervention (p < .001) and shorter hospital stays (p = .028). Factors associated with a higher incidence of CSF leakage included posterior fossa procedures, reinterventions, and the need for CSF drainage placement. PCC reduced the risk of suffering CSF leakage by more than 75% (p = .002) once adjusted for age, surgical approach, type of cranial opening, reintervention, CSF drainage, dural substitute, and dural defect coverage.

CONCLUSIONS

Our findings confirm PCC as an effective means of preventing CSF leakage following cranial neurosurgery with fewer associated complications.

Для цитирования: Sánchez Fernández Carlos, Rodríguez-Arias Carlos Alberto. Evaluation of the safety and effectiveness of a sealant hemostatic patch for preventing cerebrospinal fluid leaks in cranial surgery.. Expert review of medical devices. 2021. DOI: 10.1080/17434440.2021.1988850.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.