m+Medelevator.RU
← Поиск публикаций
European journal of radiology · 2024

Automatic detection of pulmonary embolism on computed tomography pulmonary angiogram scan using a three-dimensional convolutional neural network.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhu Huiyuan, Tao Guangyu, Jiang Yifeng, Sun Linlin, Chen Jing, Guo Jia, Wang Na, Wei Hongrong, Liu Xinglong, Chen Yinan, Yan Zhennan, Chen Qunhui, Sun Xiwen, Yu Hong

Аннотация

OBJECTIVE: To propose a convolutional neural network (EmbNet) for automatic pulmonary embolism detection on computed tomography pulmonary angiogram (CTPA) scans and to assess its diagnostic performance.

METHODS: 305 consecutive CTPA scans between January 2019 and December 2021 were enrolled in this study (142 for training, 163 for internal validation), and 250 CTPA scans from a public dataset were used for external validation. The framework comprised a preprocessing step to segment the pulmonary vessels and the EmbNet to detect emboli. Emboli were divided into three location-based subgroups for detailed evaluation: central arteries, lobar branches, and peripheral regions. Ground truth was established by three radiologists.

RESULTS: The EmbNet's per-scan level sensitivity, specificity, positive predictive value (PPV), and negative predictive value were 90.9%, 75.4%, 48.4%, and 97.0% (internal validation) and 88.0%, 70.5%, 42.7%, and 95.9% (external validation). At the per-embolus level, the overall sensitivity and PPV of the EmbNet were 86.0% and 61.3% (internal validation), and 83.5% and 57.5% (external validation). The sensitivity and PPV of central emboli were 89.7% and 52.0% (internal validation), and 94.4% and 43.0% (external validation); of lobar emboli were 95.2% and 76.9% (internal validation), and 93.5% and 72.5% (external validation); and of peripheral emboli were 82.6% and 61.7% (internal validation), and 80.2% and 59.4% (external validation). The average false positive rate was 0.45 false emboli per scan (internal validation) and 0.69 false emboli per scan (external validation).

CONCLUSION: The EmbNet provides high sensitivity across embolus locations, suggesting its potential utility for initial screening in clinical practice.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049