Routine fluoroscopic guidance is not required for placement of Hickman catheters via the supraclavicular route.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Apsner R, Schulenburg A, Sunder-Plassmann G, Muhm M, Keil F, Malzer R, Kalhs P, Druml W

Аннотация

The purpose of this study was to evaluate the efficacy and safety in placement of Hickman catheters via the supraclavicular route without fluoroscopic guidance. We studied 81 consecutive percutaneous placements of dual lumen Hickman catheters via the supraclavicular route without the use of fluoroscopic guidance. Success rates, technical problems, complications, infections and reasons for explantation were recorded prospectively. Seventy-nine punctures were successful (97.5%). One pneumothorax (1.2%) and three accidental arterial punctures (3.7%) occurred. Difficulties in introducing the catheter through the peel away sheath or misplacement were not observed. The catheters remained in place for a total of 7657 days (mean 94.5, range 3-392 days). Sixteen blood cultures were positive (2.1/1000 catheter days). Five catheters (6.1%) were lost because of mechanical complications. Forty-two lines (52%) were removed electively, 23 (28.4%) because of suspected infection, and two (2.5%) because of tunnel infection. Nine patients died with a functioning catheter. We conclude that the supraclavicular approach to the subclavian vein is safe and efficient for introduction of Hickman catheters. Using this access, routine fluoroscopic or sonographic guidance is not required for proper placement. Implantation of the lines in an intensive care unit did not lead to higher infection rates than those reported in the literature.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты