Pediatrics and neonatology · 2024
Effectiveness of corticosteroids and epinephrine use in neonates for the first extubation attempt: A retrospective study.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yeh Chen-Yu, Chang Yu-Jun, Chen Lih-Ju, Lee Cheng-Han, Chen Hsiao-Neng, Chen Jia-Yuh, Hsiao Chien-Chou
Аннотация
BACKGROUND: This study aimed to analyze the use of corticosteroids and epinephrine in neonates for the first extubation attempt and compared clinical characteristics of infants with successful and failed extubation events.
METHODS: This was a retrospective cohort study conducted at a single level III neonatal intensive care unit in Taiwan. The study included 215 infants born between 2020 and 2021 who had been intubated for more than 48 h before their first extubation attempt. We compared perinatal and peri-extubation characteristics and outcomes between the two groups. Successful extubation was defined as freedom from invasive ventilatory support 72 h after extubation. The relationship between corticosteroids, local epinephrine, and successful extubation was determined using multivariate logistic regression analysis.
RESULTS: In the univariate analysis, the failed extubation group received a significantly higher proportion of intravenous dexamethasone (p = 0.006) than the successful extubation group. Furthermore, the failed extubation group had a longer duration of nebulized epinephrine (p = 0.034) and more episodes of local application of epinephrine to the superior larynx (p = 0.003) than the successful extubation group. Multivariate analysis revealed that the absence of lung atelectasis, tachycardia 72 h after extubation, and lower post-extubation PCO2 were the key factors associated with successful extubation.
CONCLUSIONS: There were trends toward systemic dexamethasone, local application of epinephrine to the superior larynx, and longer duration of nebulized epinephrine in the reintubation group. However, corticosteroid or local epinephrine use was not significantly associated with successful extubation. Lung atelectasis, elevated levels of carbon dioxide, and tachycardia were identified as risk factors for extubation failure.
METHODS: This was a retrospective cohort study conducted at a single level III neonatal intensive care unit in Taiwan. The study included 215 infants born between 2020 and 2021 who had been intubated for more than 48 h before their first extubation attempt. We compared perinatal and peri-extubation characteristics and outcomes between the two groups. Successful extubation was defined as freedom from invasive ventilatory support 72 h after extubation. The relationship between corticosteroids, local epinephrine, and successful extubation was determined using multivariate logistic regression analysis.
RESULTS: In the univariate analysis, the failed extubation group received a significantly higher proportion of intravenous dexamethasone (p = 0.006) than the successful extubation group. Furthermore, the failed extubation group had a longer duration of nebulized epinephrine (p = 0.034) and more episodes of local application of epinephrine to the superior larynx (p = 0.003) than the successful extubation group. Multivariate analysis revealed that the absence of lung atelectasis, tachycardia 72 h after extubation, and lower post-extubation PCO2 were the key factors associated with successful extubation.
CONCLUSIONS: There were trends toward systemic dexamethasone, local application of epinephrine to the superior larynx, and longer duration of nebulized epinephrine in the reintubation group. However, corticosteroid or local epinephrine use was not significantly associated with successful extubation. Lung atelectasis, elevated levels of carbon dioxide, and tachycardia were identified as risk factors for extubation failure.