MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2013.09.006

Медицинская библиотека · Journal of chromatography. A · 2013

Planar chromatography mediated screening of tetracycline and fluoroquinolone antibiotics in milk by fluorescence and mass selective detection.

Chen Yisheng, Schwack Wolfgang

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A rapid and efficient method for preliminary screening of four tetracyclines (tetracycline, chlortetracycline, oxytetracycline, doxycline) and three fluoroquinolones (enrofloxacin, ciprofloxacin, marbofloxacin), mostly detected in milk, by high-performance thin-layer chromatography-fluorescence detection and electrospray ionization mass spectrometry (HPTLC-FLD-ESI/MS) is highlighted. The optimized separation of the target antibiotics on ethylenediamine tetraacetic acid modified silica gel plates showed marked benefits for screening purposes. Besides, selective and sensitive densitometry in fluorescence mode was established with excitation at 366nm for the tetracyclines, 300nm for enrofloxacin and ciprofloxacin, and 280nm for marbofloxacin. Limits of detection (LOD) and quantitation (LOQ) with 95% confidence were in the range of 12-25 and 45-95μg/kg, respectively, in milk samples. Recoveries of target antibiotics from milk samples spiked at three critical levels (50, 100 and 150μg/kg) ranged from 76% to 105%. More importantly, a mass selective detection (MSD) was established as additional tool for confirmatory purposes. Using the elution-head based TLC-MS interface, the optimized elution flow consisting of acetonitrile/ammonium formate buffer (9/1, v/v) at a rate of 0.3mL/min enabled time-dependent resolution of analytes from the major interfering compounds, thus circumventing serious ion suppression effects. The established MSD assay also offered high sensitivity (25μg/kg) for confirmation, meeting Commission Regulation (EU) No. 37/2010.

Для цитирования: Chen Yisheng, Schwack Wolfgang. Planar chromatography mediated screening of tetracycline and fluoroquinolone antibiotics in milk by fluorescence and mass selective detection.. Journal of chromatography. A. 2013. DOI: 10.1016/j.chroma.2013.09.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.