Distal femoral fractures in post-poliomyelitis patients treated with locking compression plates.
Аннотация
OBJECTIVE
Treatment of distal femoral fracture in post-polio patients is difficult because the bone is usually osteopenic, small and deformed. This retrospective study aimed to investigate the outcomes of distal femoral fracture in post-polio patients treated by locking compression plates (LCP).
METHODS
The medical records of 19 post-polio patients (mean age 49 years at time of surgery) were reviewed and intraoperative data retrieved. Fracture union and callus formation were evaluated on radiographs taken at each postoperative visit. Functional outcome assessments included range of motion and Hospital for Special Surgery (HSS) score of the ipsilateral knee joint.
RESULTS
Sixteen femoral fractures occurred in the poliomyelitis-affected limbs. The mean duration of operation was 86 min and mean blood loss 120 mL. All fractures healed (mean, four months) but union was delayed in one. At the final follow-up 2 yrs after surgery, the mean range of knee flexion was 105° (range, 90°-130°), and mean HSS score 76 points (range, 60-93). There were no cases of nonunion, implant cutout, or other complications.
CONCLUSIONS
LCP provides stable fixation of distal femoral fractures in post-polio patients. Bony union and good functional outcomes are achieved, but delayed union and minimal callus may occur.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.