MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.phro.2024.100608

Медицинская библиотека · Physics and imaging in radiation oncology · 2024

Validation of quantitative magnetic resonance imaging techniques in head and neck healthy structures involved in the salivary and swallowing function: Accuracy and repeatability.

Guerreiro F, van Houdt P J, Navest R J M, Hoekstra N, de Jong M, Heijnen B J, Zijlema S E, Verbist B, van der Heide U A, Astreinidou E

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Radiation-induced damage to the organs at risk (OARs) in head-and-neck cancer (HNC) patient can result in long-term complications. Quantitative magnetic resonance imaging (qMRI) techniques such as diffusion-weighted imaging (DWI), DIXON for fat fraction (FF) estimation and T2 mapping could potentially provide a spatial assessment of such damage. The goal of this study is to validate these qMRI techniques in terms of accuracy in phantoms and repeatability in-vivo across a broad selection of healthy OARs in the HN region.

MATERIALS AND

METHODS

Scanning was performed at a 3 T diagnostic MRI scanner, including the calculation of apparent diffusion coefficient (ADC) from DWI, FF and T2 maps. Phantoms were scanned to estimate the qMRI techniques bias using Bland-Altman statistics. Twenty-six healthy subjects were scanned twice in a test-retest study to determine repeatability. Repeatability coefficients (RC) were calculated for the parotid, submandibular, sublingual and tubarial salivary glands, oral cavity, pharyngeal constrictor muscle and brainstem. Additionally, a linear mixed-effect model analysis was used to evaluate the effect of subject-specific characteristics on the qMRI values.

RESULTS

Bias was 0.009x10-3 mm2/s for ADC, -0.7 % for FF and -7.9 ms for T2. RCs ranged 0.11-0.25x10-3 mm2/s for ADC, 1.2-6.3 % for FF and 2.5-6.3 ms for T2. A significant positive linear relationship between age and the FF and T2 for some of the OARs was found.

CONCLUSION

These qMRI techniques are feasible, accurate and repeatable, which is promising for treatment response monitoring and/or differentiating between healthy and unhealthy tissues due to radiation-induced damage in HNC patients.

Для цитирования: Guerreiro F, van Houdt P J, Navest R J M, Hoekstra N, de Jong M, Heijnen B J, Zijlema S E, Verbist B, van der Heide U A, Astreinidou E. Validation of quantitative magnetic resonance imaging techniques in head and neck healthy structures involved in the salivary and swallowing function: Accuracy and repeatability.. Physics and imaging in radiation oncology. 2024. DOI: 10.1016/j.phro.2024.100608.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.