DOI 10.1016/j.ejrad.2024.111581
AI-based automated evaluation of image quality and protocol tailoring in patients undergoing MRI for suspected prostate cancer.
Аннотация
PURPOSE: To develop and validate an artificial intelligence (AI) application in a clinical setting to decide whether dynamic contrast-enhanced (DCE) sequences are necessary in multiparametric prostate MRI.
METHODS
This study was approved by the institutional review board and requirement for study-specific informed consent was waived. A mobile app was developed to integrate AI-based image quality analysis into clinical workflow. An expert radiologist provided reference decisions. Diagnostic performance parameters (sensitivity and specificity) were calculated and inter-reader agreement was evaluated.
RESULTS
Fully automated evaluation was possible in 87% of cases, with the application reaching a sensitivity of 80% and a specificity of 100% in selecting patients for multiparametric MRI. In 2% of patients, the application falsely decided on omitting DCE. With a technician reaching a sensitivity of 29% and specificity of 98%, and resident radiologists reaching sensitivity of 29% and specificity of 93%, the use of the application allowed a significant increase in sensitivity.
CONCLUSION
The presented AI application accurately decides on a patient-specific MRI protocol based on image quality analysis, potentially allowing omission of DCE in the diagnostic workup of patients with suspected prostate cancer. This could streamline workflow and optimize time utilization of healthcare professionals.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.