MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Zhonghua er bi yan hou tou jing wai ke za zhi = Chinese journal of otorhinolaryngology head and neck surgery · 2009

[Value of pulse transit time in detecting respiratory drive].

Huang Hui, Ye Jing-ying, Li Yan-ru, Wang Xiao-yi, Zhang Yu-huan, Wang Jiang-yong, Ding Xiu, Li Hong-guang, Yin Guo-ping, Cheng Chen-jing

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To assess the accuracy of pulse transit time (PTT) in classification of apnea events, and collect data for clinical application reference.

METHODS

Thirty-two obstructive sleep apnea-hypopnea syndrome (OSAHS) patients included in the research had Polysomnography (PSG), and 10 305 apnea events were recorded. All the events were analyzed by PTT and esophageal pressure (Pes) respectively. The results were analyzed to assess the accuracy of PTT and compare the accuracy of pulse transit time between REM stage and NREM stage, and analyze the correlation between age, body mass index (BMI), apnea hypopnea index (AHI) and concordance rate in every patient.

RESULTS

The total concordance rate between PTT and Pes in classification of apnea was 96.7% (9970/10305). The sensitivities of PTT in detecting central, mixed and obstructive apnea were 88.0%, 91.3% and 97.8% respectively and the specificities were 99.8%, 97.8% and 92.8% respectively. The false determinations of apnea events mainly concentrated on the false determinations between the obstructive and mixed apnea. There was no statistical significant between the accuracy of PTT in different sleep stages. There was a negative relationship between the age, BMI, Lowest SaO2, AHI and the concordance rate.

CONCLUSIONS

There was good concordance between PTT and Pes in classification of apnea. PTT had very high sensitivity and specificity in detecting all kinds of apnea. This study showed that PTT can detect respiratory drive noninvasively with high accuracy.

Для цитирования: Huang Hui, Ye Jing-ying, Li Yan-ru, Wang Xiao-yi, Zhang Yu-huan, Wang Jiang-yong, Ding Xiu, Li Hong-guang, Yin Guo-ping, Cheng Chen-jing. [Value of pulse transit time in detecting respiratory drive].. Zhonghua er bi yan hou tou jing wai ke za zhi = Chinese journal of otorhinolaryngology head and neck surgery. 2009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.