m+Medelevator.RU
← Поиск публикаций
BMJ open quality · 2022

Reducing laboratory costs through rational testing in suspected pre-eclampsia.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jakes Adam Daniel, Cox Marsha, Drane Simon, Johnson Antoinette

Аннотация

The current electronic laboratory order set at Epsom and St Helier University Hospitals NHS Trust for suspected pre-eclampsia includes a full blood count, urea and electrolytes, liver function, gamma-glutamyltransferase and uric acid. Local and national guidelines do not recommend the use of gamma-glutamyltransferase or uric acid for the investigation or monitoring of pre-eclampsia, as they are poor predictors of maternal and neonatal outcomes. We aimed to remove the automatic inclusion of gamma-glutamyltransferase and uric acid from the electronic laboratory order set for suspected pre-eclampsia. Stakeholders were approached to gain an understanding of whether gamma-glutamyltransferase and uric acid were being used in the clinical assessment of suspected pre-eclampsia. Obstetric consultants and maternity staff confirmed that they do not use uric acid in their clinical assessment, despite the laboratory phoning with abnormal results. In addition, an isolated gamma-glutamyltransferase rise is of no particular significance and is not part of the National Institute for Health and Care Excellence (NICE) diagnostic criteria for pre-eclampsia. The baseline number of gamma-glutamyltransferase and uric acid requests from the maternity department was identified over 2 months. The hospital information technology service was then asked to remove gamma-glutamyltransferase and uric acid from the electronic laboratory order set. The number of gamma-glutamyltransferase and uric acid requests from the maternity department following the intervention was identified over 2 months. A significant reduction in both gamma-glutamyltransferase and uric acid requests were noted. In addition, the midwives within the maternity assessment unit noted a significant reduction in phone calls from the laboratory to escalate abnormal blood results. This has saved the trust money and reduced staff time answering phone calls regarding abnormal blood results. A repeat assessment at 8 months following the removal of gamma-glutamyltransferase and uric acid demonstrated sustainability of the project.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты