MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/pcc.0b013e3182231882

Медицинская библиотека · Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2012

A multicenter randomized controlled trial comparing effectiveness of two nasal continuous positive airway pressure devices in very-low-birth-weight infants.

Bober Klaudiusz, Świetliński Janusz, Zejda Jan, Kornacka Katarzyna, Pawlik Dorota, Behrendt Jakub, Gajewska Elżbieta, Czyżewska Małgorzata, Korbal Piotr, Witalis Janusz, Walas Wojciech, Wilińska Maria, Turzańska Agnieszka, Zieliński Grzegorz, Czeszyńska Beata, Bachman Thomas

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Many studies suggest nasal continuous positive airway pressure is an effective and relatively complication-free means of respiratory support in premature infants. However, only limited data exist regarding the practical aspects of nasal continuous positive airway pressure delivery, including the best way to provide the positive airway pressure.

DESIGN

Our aim was to compare the results of treatment using two different nasal continuous positive airway pressure devices: variable flow Infant Flow and constant flow nasal continuous positive airway pressure in two different groups of very-low-birth-weight infants in a multicenter randomized controlled trial. The indication groups were elective to avoid intubation and weaning from mechanical ventilation.

SETTING

Twelve leading tertiary care neonatal centers in Poland.

PATIENTS: Among 276 infants (weighing between 750-1500g, with a gestational age ≤32 wks) enrolled, 51% were randomized to receive Infant Flow and 49% to receive constant flow nasal continuous positive airway pressure.

MEASUREMENTS AND MAIN

RESULTS

Treatment success (i.e., no need for intubation/reintubation) occurred in 75% of our patients with a nonstatistically significant advantage seen with Infant Flow. The incidence of severe nasal complications and necrotizing enterocolitis were statistically significantly lower in the infants treated with Infant Flow. In our study, factors associated with elective nasal continuous positive airway pressure failure were birth weight ≤1000 g, gestational age ≤28 wks, clinical risk index for babies score >1, and PaO(2)/FIO(2) ratio of <150. Only birth weight ≤1000 g was associated with weaning failure.

CONCLUSIONS

We found fewer severe nasal complications but no statistically significant advantage in treatment success in infants assigned to Infant Flow nasal continuous positive airway pressure compared with those assigned to constant flow nasal continuous positive airway pressure treatment. Significant risk factors of treatment failure include small size, maturity, and severity of respiratory distress syndrome.

Для цитирования: Bober Klaudiusz, Świetliński Janusz, Zejda Jan, Kornacka Katarzyna, Pawlik Dorota, Behrendt Jakub, Gajewska Elżbieta, Czyżewska Małgorzata, Korbal Piotr, Witalis Janusz, Walas Wojciech, Wilińska Maria, Turzańska Agnieszka, Zieliński Grzegorz, Czeszyńska Beata, Bachman Thomas. A multicenter randomized controlled trial comparing effectiveness of two nasal continuous positive airway pressure devices in very-low-birth-weight infants.. Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies. 2012. DOI: 10.1097/pcc.0b013e3182231882.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.