m+Medelevator.RU
← Поиск публикаций
BJA open · 2025

The 3-Minute Diagnostic Confusion Assessment Method severity score correlates with the Delirium Rating Scale-Revised-98 and with biomarkers of delirium.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rivera Cameron, Kunkel David, Her Maihlee, Qureshi Simran, Pearce Robert A, Sanders Robert D, Lennertz Richard

Аннотация

BACKGROUND: Several methods are used to measure delirium severity in the postoperative period. Here, we compare severity scores from two common assessment methods: the 3-Minute Diagnostic Confusion Assessment Method (3D-CAM) and the Delirium Rating Scale-Revised-98 (DRS).

METHODS: Data were collected as part of an ongoing observational cohort study of perioperative delirium in patients >65 yr old undergoing major elective surgery with an anticipated hospital stay of at least 2 days. Patients were excluded if they had a documented history of dementia, resided in a nursing home, underwent neurosurgery, or could not complete neurocognitive testing. Patients underwent paired 3D-CAM and DRS assessments before and after operation along with EEG, cognitive testing, and plasma biomarker analysis.

RESULTS: Of 226 subjects enrolled, 204 completed both the 3D-CAM and DRS assessments. Peak 3D-CAM severity (3D-CAM-S) scores correlated with peak DRS severity scores, for both the raw (ρ=0.74, P<0.001) and short form method (ρ=0.66, P<0.001). Peak 3D-CAM-S raw scores also correlated with delirium duration and severity duration area under the curve measures (ρ=0.71, P<0.001 and ρ=0.91, P<0.001, respectively). Similar to prior reports with the DRS, 3D-CAM-S raw scores correlated with worse performance on the Trail Making Test B (ρ=0.37, P<0.001, n=177), slow-wave electroencephalogram power (ρ=0.3, P=0.001, n=73), and plasma neurofilament light (ρ=0.26, P<0.05, n=61) and tau (ρ=0.41, P<0.001, n=63).

CONCLUSIONS: The 3D-CAM-S severity scores correlated with DRS, delirium duration, and biomarkers of delirium. The 3D-CAM, which is easier to implement than the DRS in postoperative patients, may provide a comparable assessment of delirium severity in this population.

CLINICAL TRIAL REGISTRATION: NCT03124303.