MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/icvts/ivaf112

Медицинская библиотека · Interdisciplinary cardiovascular and thoracic surgery · 2025

Thoracoscopic resection of residual aneurysm following hybrid aortic arch repair to prevent secondary aorto-oesophageal fistula in cases of severe oesophageal compression.

Yamana Fumio, Shimamura Kazuo, Funaki Soichiro, Miyagawa Shigeru

СтатьяКлинический случайПеревод в очереди

Аннотация

Secondary aorto-oesophageal fistulas after thoracic endovascular aortic repair are a severe complication associated with high mortality rates. We present a case of staged oesophageal decompression performed via thoracoscopic resection of a residual aneurysm following thoracic endovascular aortic repair to prevent secondary aorto-oesophageal fistulas in a patient with a distal arch aneurysm causing significant oesophageal compression. A 70-year-old woman with a 3-month history of hoarseness was referred to our hospital. Computed tomography revealed a penetrating ulcer in the aortic arch, complicated by a 60 mm pseudoaneurysm causing significant oesophageal compression. Owing to multiple comorbidities, the patient had high perioperative risk, rendering total arch replacement unfeasible; therefore, endovascular repair was selected. After Zone 1 hybrid thoracic endovascular aortic repair, complete thrombosis of the aneurysm was confirmed. Staged residual aneurysm resection was performed via thoracoscopy through a small left thoracotomy relieve oesophageal compression. Two years postoperatively, computed tomography revealed aneurysmal reduction, complete resolution of the oesophageal pressure drainage and no evidence of secondary aorto-oesophageal fistula or stent graft infection.

Для цитирования: Yamana Fumio, Shimamura Kazuo, Funaki Soichiro, Miyagawa Shigeru. Thoracoscopic resection of residual aneurysm following hybrid aortic arch repair to prevent secondary aorto-oesophageal fistula in cases of severe oesophageal compression.. Interdisciplinary cardiovascular and thoracic surgery. 2025. DOI: 10.1093/icvts/ivaf112.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.